FOXBORO FBMSVH – Foxboro Fieldbus Module
Low Temperature Operative Limit of Electronics Housing Extended Down to -50°C (-58°F)
Not available with sensors and seals with Inert fill, Structure Codes 78 and 79.
or DIN Options -D2. -D4. -D6. and -D8
Vent Screw in side of Process Cover (with 316 ss process covers only)
Not available with seals, DIN construction options, or Structure Codes 78 and 79
Model-J-V (h)
Supplemental Customer Tag (Stainless Steel Tag wired onto Transmitter)
Examples: IGP20-D20B21F-M1Z2; IAP20-DS3C11F-T-T
a. Maximum overrange pressure is 2.1 MPa (300 psi); temperature limits are -7 and +82°C (20 and 180°F).
b. Transmitter and Pressure Seal Model Codes are both required. See PSS 2A-1Z11 A for the various pressure seal model codes.
c. Remote Seal Models that may be specified are PSFPS, PSFES, PSFAR, PSTAR, PSISR, PSSCR, and PSSSR.
d. Span Limit Code A is not available with pressure seals (Structure Codes F1. F2. S3. S4. SC, SD).
e. Span Limit Codes E and F are not available with Structure Codes 78 and 79 (PVDF insert in HI Side Cover).
A cover lock is provided as standard with Electrical Safety Codes D, B, G, and V.
g. Not available when Remote Mount or Direct Connect Pressure Seals are specified.
h. Pressure derated. See derating table in specifications section.
Temperature limits derated to 0 and 60°C (32 and 140°F). Also Mounting Sets -M1 and -M2 not available.
When -X3 is specified, the standard bolting is replaced with 17-4 ss bolts and nuts. Therefore, there is no need to specify Option-B2
when selecting the Chlorine Service Option -X3.
| PACIFIC | 6410-001-N-N-N |
| PACIFIC | 6410-009-N-N-N |
| PACIFIC | 6445-001-K-N |
| PACIFIC | LA23GCKC-1G |
| PACIFIC | LA23GCKC-1Y |
| PACIFIC | LA23GCKC-P500A |
| PACIFIC | LA23GCKX-P500A |
| PACIFIC | PC3406AI-001-E |
| PACIFIC | SCE904AN-002-01 |
| PACIFIC | VDE0530-S1 |
| PACIFIC SCIENTIFIC | 6410-009-N-N-N |
| PACIFIC SCIENTIFIC | E32NCHA-LNN-NS-00 |
| PACIFIC SCIENTIFIC | H32NCHA-LNN-NS-00 |
| PACIFIC SCIENTIFIC | R43HCNA-R2-NS-VS-00 |
| PACIFIC SCIENTIFIC | SCE903A3-002-01 |
Available with Electrical Safety Code D only.
k. Not available with DIN construction options. For stainless steel bolts with DIN construction, specify -D5 to -D8. as required.
m. Standard offering with IAP20 Transmitters when pressure seals are used. However, -G1 is a required option with IGP20 Transmitters
when pressure seal (Structure Codes S3. S4. F1. F2. SC, and SD) will be used in vacuum applications. This option substitutes
vacuum service metal gasket for standard PTFE process cover gasket
TRADITIONAL STRUCTURE (Figure8)
This structure is where the process connections
are at 90° from the transmitter centerline.
Vertical and horizontal mounting are provided for
sensor cavity venting and draining.
LOW PROFILE STRUCTURE LP1 (Figure9)
This structure has process connections that are
in line with the transmitter centerline. It is
compact, and its light weight is ideal for direct
mounting to the process. An adapter plate
(Options -P1 to -P8), shown in Figure10 with the
LP2. is offered for mounting to a Coplanar™
manifold. Sensor cavity venting and draining is
provided for both vertical and horizontal
installations.
LOW PROFILE STRUCTURE LP2 (Figure10)
This structure, as with the LP1. is an in-line
design which can be direct or bracket mounted.
It is used for vertical installations, and can also
be installed on existing Coplanar manifolds
using an adapter plate (Options -P1 to -P8).
Sensor cavity venting and draining are also
provided.
Wide Rangeability
Five d/p Cell range sensors cover measurement
spans from 0.125 kPa to 21 MPa (0.5 inH2O to
3000 psi). This high turndown capability means that
most differential pressure applications are satisfied
with only these five ranges, simplifying your spare
transmitter and spare parts requirements.
Sensor Corrosion Protection
Choice of 316L ss, Co-Ni-Cr, Nickel alloy, Monel,
Gold-Plated 316L ss, and Tantalum materials. High
corrosion resistance of Co-Ni-Cr (TI 037-078) means
long service life without extra cost for exotic
materials. See TI 37-75b for process applicability
with Co-Ni-Cr and other wetted parts materials.
Flameproof Design
Meet Agency flameproof and zone requirements.
Process Connectors
Removable, gasketed process connectors allow a
wide range of selections, including 1/4 NPT,
1/2 NPT, Rc 1/4. Rc 1/2. and weld neck connections.
For very corrosive chemical processes, 1/2 NPT
PVDF inserts are installed in the HI- and LO-side
316 ss covers when a traditional structure is used,
and used as the process connectors.