KEBA KETOP T50 012 CES / 69767 / 08 Teach Pendant + WB095 Wall Mount
Digital outputs
DO 242/B DO 272/A
Number of outputs 8 14
Nominal voltage 24 V DC
Processing time 1 ms
Nominal current of digital outputs 2 A at 50 % simultaneity
Galvanic isolation Yes
Status display Orange LED
Protection facility Short-circuit protection
Max. inductive load 1 J at max 0.2 Hz
Dimensions, weight
Height 120 mm
Width 22.5 mm front plate / 32.5 mm incl. plug
Depth 100 mm
Weight 130 g
General
DO 242/B DO 272/A
Supply voltage 24 V DC from front (nominal voltage tolerance: 19.2 V … 30 V, acc. to EN 61131-2)
24 V DC from K-bus, 5 V DC from K-bus
Overvoltage category II
Protection class III acc. to EN 61131-2
Addressing on K-bus Via 16-digit address switch, on the side
Type of terminals Open – pitch 5.08 mm
Displays on the front plate 16 signal status LEDs
Max. power consumption K-bus 24 V 2.1 W 2.1 W
Max. power consumption K-bus 5 V 0.4 W 0.4 W
Product features
• Up to 8 digital inputs
• 8 digital 2 A outputs
• 2 digital inputs with interrupt
• Short-circuit detection
• Permanently short-circuit proof
• Electronic rating plate
Short description
The DM 27x/A series is a digital input/output module of the KeConnect C2 product line and enables the connection of 6
or 8 digital inputs and 8 digital outputs. 24 V DC control signals are captured by the digital inputs and transmitted galva
nically isolated to the higher-level automation device. In addition, two of the digital inputs can be used as interrupt inputs.
The digital outputs switch the 24 V DC control signals of a CPU module galvanically isolated from the connected actua
tors. In addition to the short-circuit connection, outputs that cause short circuits can be switched off individually.
This module is attached directly to a CPU module or can be operated with all KEBA controls by means of a bus coupler