Sensor Corrosion Protection

Choice of 316L ss, Co-Ni-Cr, Nickel alloy, Monel,

Tantalum, and Gold-Plated 316L ss materials. High

corrosion resistance of Co-Ni-Cr (TI 037-078) means

long service life in many difficult applications without

the extra cost for exotic materials. Also see TI 37-75b

for process applicability with Co-Ni-Cr and other

wetted parts materials.

Wide Rangeability

Gauge pressure measurement spans may be as low

as 0.12 kPa (0.5 inH2O) to as high as 35 MPa

(5000 psi) by choosing one of only six sensors, and

absolute pressure measurement spans may be as

low as 0.87 kPa (3.5 inH2O) to as high as 21 MPa

(3000 psi) by choosing one of only four sensors.

This provides exceptional measurement range

capability with a minimum of versions.

Process Connector

Removable, gasketed process connector (Figure 6)

allows a wide range of selections, including 1/4 NPT,

1/2 NPT, Rc 1/4. Rc 1/2. and weld neck connections.

For highly corrosive chemical processes, a 1/2 NPT

PVDF (Kynar) insert is installed in the HI-side 316 ss

cover and is used as the process connector. In these

applications, tantalum is used as the sensor

diaphragm materi

MOX MX603-2007-01
MOXA EDS-408A-MM-SC
M-SYSTEM MD2202-D32-X-P
MTL 2213
MTL 4073
MTL 5541
MTL 8103-AI-TX
MTL 8104-AO-IP
MTL 8502-BI-DP
MTL 8505-BI-MB
MTL 8604-FT-FU
MTL 8711-CA-NS
MTL 8715-CA-BI
MTL 8724-CA-PS
MTL 8811-IO-DC
MTL 8937-HN
MTL 8939-HN

Flameproof Design

The transmitters are designed to meet Agency

flameproof and zone requirements.

Ease of Mounting Optional Two-Valve Manifold

Two-valve manifold, to isolate transmitter and to vent

pressure, is easily mounted directly to transmitter.

Vacuum Service

An LRL of -100 kPa (-14.7 psi, -1 bar) means that

vacuum measurements are easily handled with the

versatile IGP20 transmitter.

Vibration Effect

Total effect is ±0.2% of URL per “g” for vibrations in

the frequency range of 5 to 500 Hz; with a double

amplitude (DA) of 6.3 mm (0.25 in) in the range of 5

to 15 Hz, or accelerations of 3 “g” in the range of 15

to 500 Hz, whichever is smaller, for transmitters with

aluminum housings; and with a DA of 6.3 mm

(0.25 in) in the range of 5 to 9 Hz, or accelerations of

1 “g” in the range of 9 to 500 Hz, whichever is

smaller, for transmitters with 316 ss housings.

Process Wetted Materials

PROCESS CONNECTION

316L ss, cs, Monel, or Nickel alloy, or PVDF

SENSOR DIAPHRAGM

316L ss, Co-Ni-Cr, Monel, Tantalum, Nickel

alloy, or Gold-Plated 316L ss

GASKET

Glass-filled PTFE

Pressure Seal Diaphragm Material

Varies with pressure seal selected.

Reference Side Materials

Cover is 316 ss, and sensor diaphragm material is

same as for process wetted materials above.

Fill Fluid

Silicone Oil or Inert FC43. as specified.

Dimensions

Refer to “DIMENSIONS – NOMINAL” on page 36

and to Dimensional Print DP 020-447.

Approximate Mass

3.5 kg (7.8 lb) – with Aluminum Housing

4.2 kg (9.2 lb) – with Process Connectors

Add 1.1 kg (2.4 lb) – with 316 ss Housing

With Pressure Seals: See PSS 2A-1Z11 A.