Foxboro SY-60399001R SY-60301001RB SY-60702001RA/SY-61025006RA/SY-61025004RA/SY-61025001RA Control Module
The Intrinsically Safe I/O Subsystem provides integration between the Pepperl+Fuchs™ (P+F) modular
intrinsically safe remote I/O systems and the I/A Series® system. The Intrinsically Safe Communications
Module (ISCM) enables I/A Series control processors to view the P+F I/O modules as equivalent 200 Series
Fieldbus Modules (FBMs), which can be monitored with standard I/A Series blocks and standard InFusion™
or I/A Series system/control configurator applications such as the InFusion Engineering Environment and the
Integrated Control Configurator.
FEATURES
Intrinsically safe – supports Zone 2. Div. 2 or
Zone 22 (LB-style) environments or Zone 1. or
Zone 21 (FB-style) environments
ISCMs interface the 2 Mbps HDLC Module
Fieldbus to the FCP270 or ZCP270
Up to 46 (for LB-style Zone 2 Applications) or
48 (for FB-style Zone 1 Applications) P+F
intrinsically safe I/O modules supported per
optionally redundant ISCM, with a total of
16 ISCMs supported per I/A Series control
processor (FCP270 or ZCP270); a maximum of
204 modules (ISCMs, I/O modules and
200 Series FBMs) supported per FCP270 and a
maximum of 128 modules supported per
ZCP270. provided the maximum CP Fieldbus
load and intrinsically safe I/O power supply load is
not exceeded
Redundant ISCMs allow either module to control
the process. Role reversal is automatic on
detected failures
Letterbug set through a letterbug module with
rotary switch plugged into the ISCM.
Monitored by standard System Manager or
I/A Series SMDH and FoxView™ displays
“CE” logo marked on product.
OVERVIEW
The Intrinsically Safe I/O Subsystem provides
integration between the Pepperl+Fuchs (P+F)
modular intrinsically safe remote I/O systems and the
I/A Series system. The Intrinsically Safe
Communications Module (ISCM) communicates
between the two systems, as it enables I/A Series
control processors to view supported P+F intrinsically
safe I/O modules as equivalent 200 Series Fieldbus
Modules (FBMs) over the I/A Series 2 Mbps HDLC
Fieldbus. This allows the I/O modules to be
monitored with standard I/A Series blocks and
standard I/A Series or InFusion system/control
configurator applications such as InFusion
Engineering Environment and ICC.
This subsystem supports both the P+F intrinsically
safe I/O modules and their associated base,
extension or redundancy units for Zone 2. Div. 2 or
Zone 22 (LB-style(1)) environments or
Zone 1 or Zone 21 (FB-style(2)) environments.
Optionally redundant ISCMs are mounted directly on
the appropriate P+F unit along with the I/O modules
and power supplies, as shown in Figure 1 and
Figure 2. Only I/O modules can be mounted in the
extension units. Each I/O module can be plugged
into any desired slot on the base or extension unit.
ISCMs and power supplies are required to be
plugged into their own dedicated slots.