The audience for this document is the Specifying or System

Engineer, the operating personnel and the troubleshooting

personnel. This document will guide the system user to apply

and program the FP-5000. The document will provide operating

information, enabling the operating user to start and trip the

breaker associated with the FP-5000. The operator can refer to

this publication regarding any operation of the FP-5000. This

document will also provide information to program the FP-5000

and use the troubleshooting features to collect and analyze

historical, trending and oscillographic data.

Safety and Caution Notices/Disclaimers

This technical document is intended to cover most aspects

associated with the installation, application, operation and

maintenance of the Eaton FP-5000 Protective Relay. It is provided

as a guide for authorized and qualified personnel only in the

selection and application of the FP-5000 Protective Relay. Please

refer to the specific WARNINGS and CAUTIONS that follow

before proceeding. If further information is required by the

purchaser regarding a particular installation, application or

maintenance activity, a Eaton representative should be

contacted.

Woodward easYgen-3200XT-P1
ABB :KS D211 A101
moog G771K200A H19FOFA4VH4R
ABB M102-M 1TNA920611R0002
ABB TPC1582H43A1401E-T 3BHB040969R0001
ABB MD21 LCD display 1TNA920500R0002
HIMA X-CPU 01
ABB REM620 NBMNAAAACBC1BNS21G
ABB REF620 NBFNAAAACBC1BNN21G
ABB RET620 / NBTNAAAACBC1BNN21G
Emerson A6125
Triconex 9750-210
Foxboro FBM216B RH924JH
Foxboro FBM216B RH924DE
Foxboro FBM216B RH924DT
triconex 3720
Pioneer Magnetics PM3328B-6-1-3-E
VESTAS CT360 51036002

The HCU16 HART units connect to 16 general purpose field instruments

while maintaining channel to channel isolation. Resistor conditioning

options are compatible with all types of I/O cards. It allows pass-through

connections for transmitter power supply, input signal and common.

The HCU16AO unit includes HART filters for use with I/O cards that are

incompatible with HART communication signals.

Customised backplanes and connection units are available to provide

direct connection from DCS I/O cables, replacing the standard termination

boards.

Installation

a. reference to the IEC code of practice IEC 60079-14. In addition, particular industries or end

users may have specific requirements relating to the safety of their installations and these

requirements should also be met. For the majority of installations the Directive 1999/92/EC

[the ATEX Directive – safety of installations] is also applicable.

b. Unless already protected by design, this equipment must be protected by a suitable enclosure

against:

i) mechanical and thermal stresses in excess of those noted in the certification documentation

and the product specification.

ii) aggressive substances, excessive dust, moisture and other contaminants.

c. This equipment is intrinsically safe electrical apparatus and is normally mounted in a hazardous

area. When mounted in a Zone1 location the apparatus must be provided with an enclosure,

which offers an additional degree of protection appropriate to the area classification.

Read also the Special Conditions for Safe Use for any additional or more specific information.