Eaton XV-152-D6-10TVR-10 150609 Touch Panel
The audience for this document is the Specifying or System
Engineer, the operating personnel and the troubleshooting
personnel. This document will guide the system user to apply
and program the FP-5000. The document will provide operating
information, enabling the operating user to start and trip the
breaker associated with the FP-5000. The operator can refer to
this publication regarding any operation of the FP-5000. This
document will also provide information to program the FP-5000
and use the troubleshooting features to collect and analyze
historical, trending and oscillographic data.
Safety and Caution Notices/Disclaimers
This technical document is intended to cover most aspects
associated with the installation, application, operation and
maintenance of the Eaton FP-5000 Protective Relay. It is provided
as a guide for authorized and qualified personnel only in the
selection and application of the FP-5000 Protective Relay. Please
refer to the specific WARNINGS and CAUTIONS that follow
before proceeding. If further information is required by the
purchaser regarding a particular installation, application or
maintenance activity, a Eaton representative should be
contacted.
| Woodward | easYgen-3200XT-P1 |
| ABB | :KS D211 A101 |
| moog | G771K200A H19FOFA4VH4R |
| ABB | M102-M 1TNA920611R0002 |
| ABB | TPC1582H43A1401E-T 3BHB040969R0001 |
| ABB | MD21 LCD display 1TNA920500R0002 |
| HIMA | X-CPU 01 |
| ABB | REM620 NBMNAAAACBC1BNS21G |
| ABB | REF620 NBFNAAAACBC1BNN21G |
| ABB | RET620 / NBTNAAAACBC1BNN21G |
| Emerson | A6125 |
| Triconex | 9750-210 |
| Foxboro | FBM216B RH924JH |
| Foxboro | FBM216B RH924DE |
| Foxboro | FBM216B RH924DT |
| triconex | 3720 |
| Pioneer Magnetics | PM3328B-6-1-3-E |
| VESTAS | CT360 51036002 |
The HCU16 HART units connect to 16 general purpose field instruments
while maintaining channel to channel isolation. Resistor conditioning
options are compatible with all types of I/O cards. It allows pass-through
connections for transmitter power supply, input signal and common.
The HCU16AO unit includes HART filters for use with I/O cards that are
incompatible with HART communication signals.
Customised backplanes and connection units are available to provide
direct connection from DCS I/O cables, replacing the standard termination
boards.
Installation
a. reference to the IEC code of practice IEC 60079-14. In addition, particular industries or end
users may have specific requirements relating to the safety of their installations and these
requirements should also be met. For the majority of installations the Directive 1999/92/EC
[the ATEX Directive – safety of installations] is also applicable.
b. Unless already protected by design, this equipment must be protected by a suitable enclosure
against:
i) mechanical and thermal stresses in excess of those noted in the certification documentation
and the product specification.
ii) aggressive substances, excessive dust, moisture and other contaminants.
c. This equipment is intrinsically safe electrical apparatus and is normally mounted in a hazardous
area. When mounted in a Zone1 location the apparatus must be provided with an enclosure,
which offers an additional degree of protection appropriate to the area classification.
Read also the Special Conditions for Safe Use for any additional or more specific information.