Eaton

Eaton 9465-ET-M-ST IS Media Converter Multimode

MTL9465-ET

10/100Mb Media Converter

FEATURES

♦ Intrinsically Safe ATEX / IECEx certified, FM / FMC approved

♦ Ga Ex ia IIC T4 GD (surface), Ma Ex ia I M1 (mining)

♦ Zone 1/ Division 1 mounting in a suitable enclosure

♦ Input voltage: 12V dc (10 – 15.4V)

♦ Input current: 160mA

♦ Extended temperature range (–20°C…+70°C)

♦ PoEx™ – “Power over Ethernet” powered device option – accepts module supply via the Cat5e cable*

♦ 10/100Mb Ethernet twisted pair (Cat5e) RJ45 Connection (100m max)

♦ Fibre Optic connections:

ST style 62.5/125mm Multimode (9465-ET-M-ST)

SC style 62.5/125mm Multimode (9465-ET-M-SC)

SC style 9mm Single-mode (9465-ET-S-SC)

♦ Extended distance through the use of 1300nm optics – Typically:

5Km @ 10Mbps over 62.5/125 fibre cable 2Km @ 100Mbps over 62.5/125 fibre cable

♦ Status LED’s For:

‘Power On’

Fibre Optic ‘Link 10Mb’ or ‘Link 100Mb’ Established

Fibre Optic ‘Tx/Rx Activity’

Copper UTP ‘Link 10Mb’ or ‘Link 100Mb’ Established

Copper UTP ‘Tx/Rx Activity’

♦ Transparent operation – 10/100Mbps, Full/Half Duplex with Auto-Negotiation

♦ Supports IEEE 802.3: 10Base-T, 10Base-FL, 100Base-TX and 100Base-FX/SX

♦ DIN-rail mounting module

DC power input

Note: An alternative is to supply the power via the Cat5e cable to the RJ45 connector (PoEx)

Terminal No .

+12V dc in

+12V dc in

0V

0V

5 – 8

Note:

No connection

UniOP eTOP40B-0050
ABB PM866AK02 3BSE081637R1
SARTORIUS MDB-8E
ROLLS-ROYCE SLIO 02
Bently Nevada 3500/22M-01-01-01
Alstom UT150-2
EMERSON PR6423 009-041+CON 041/913-030
Honeywell HCIX15-TE-FA-NC
KEBA D3-DU 360/A-2100-20
SARTORIUS MDB-8E
ALSTOM ALSPA CE 80-20
ALSTOM Test PLUG MMLB01
Rolls-Royce ACP-04S19-002
ABB REM545BG227AAAB
EPRO PR9376/010-011+CON021
Rolls-Royce – ACP-04S12-001 20095201
ABB RET 670*2.0-A40X00
Order = 4202183240-130
Ordering no: 1MRK004816-CE

1. (Terminals 1+2. 3+4 linked internally)

3 .3 .2 Front Panel Connectors

10/100 BASE-T Ethernet RJ45

Pin No .

Function

RX +

RX

TX +

Supply 12V – PoEx

When using PoEx – no

supply is required on these

terminals.

Supply 12V – PoEx

TX –

Supply 0V – PoEx

8

Supply 0V – PoEx

When using PoEx – no

supply is required on

screw terminals 1 to 4 – see

above.

When connecting the Cat5e cable to a 9466 Ethernet switch, or other device that supports Auto

MDI/MDI-X, a straight connected RJ45 cable is used, a cross-over cable is only required if the other

device does not support this auto detect mode.

It is recommended that Cat5e cables for Hazardous Area Zone 1 use are ‘Blue’ in colour and are

of good quality (see accessories section), the Safe Area cables being a colour other than blue to

aid identification.

10/100 BASE-FL     ST(or SC) – Fibre Optic

The fibre optic cable is connected to the ST (or SC) style ports on the front panel, the top one of

which is transmit (TX), the lower one receive (RX). When connecting fibre cable between a pair

of media converters a cross-over is required – i.e: TX on one module connects to RX on the other

module

Leave a Reply