Alstom PS421 Central Unit Module
Ethernet Executive Upload Procedure (Recommended)
Note: It isrecommended the configuration is saved before proceeding!
Enter Update Mode as described in the Update Mode section
Select ‘Executive/Boot’ from the ‘Upload New’ drop-down, then
browse and select the Executive software file to be uploaded
If the Executive file is successfully uploaded, “File Successfully
Uploaded” will appear in the dialog box
Verify the correct build and CRC information is displayed.
To apply the Executive file, click on “Apply Executive/Boot”
When the Executive file is applied successfully, “File Applied
Successfully”, will be displayed
Activate the Executive by pressing the Activate button and following the
instructions on the Web UI. Once activated, reboot the VPM-3 by either
pressing the Reset button or cycling power on the chassis.
Ethernet Application Flash Upload Procedure
(Recommended)
Note: All Parameters will be defaulted if application is changed!!
If Equipped with CI-2. XCI-2 or UCI-3. the application can be uploadedto flash
Enter Update Mode menu as described in Update Mode Section
Select ‘Application’ from the ‘Upload New’ drop down, then browse
and select the file to be uploaded. Only the b1 and mb1 file can be used
If the Application Program is successfully uploaded, “File Successfully
Uploaded” will appear in the dialog box.
To applytheApplication Program, click on ‘Apply
“File Applied Successfully”, will be displayed when successful
Clck the ‘Reset’ button or cycle power on the ElectroLogIXS
The new application file will now be selectable from the Application
Select menu on the CDU or through the web GUI.
ElectroLogIXS Memory Information
Setup and Configuration information is stored on ELX backplane Executive
version 7.26 (Crossing), 6.38(Interlocking), 8.28 (Combined) and oleder. Any
module can be swapped without losing the Setup and Configuration. Persiste101
Logs are stored on the VPM-3 module in non-volatile Flash memory.Application
equations are stored on the EPROM or can be uploaded to the (X)CI2 or UCI-3
Flash memory. An installed EPROM will override the CI flash. The
(X)CI-2 or UCI-3 can only be used with a VPM-3.
| GE | IS200EDISG1AAA |
| Prosoft | RLX2-IFH24E |
| GE | MM300-G-E-H-C-1-C-A-C-C-X-X-B-E |
| ABB | CM15/000S0E0/STD |
| Alstom | 29.139692 |
| Woodward | 8440-1575 |
| EPRO | PR6423/11R-131+CON041 |
| Foxboro | IGP10-T22D2E-M3A2 |
| GE | 850-E-P5-NN-G5-L-C-N-A-A-N-M-A-S-F-C-SE-N-N-B-4 |
| EATON | XVS-440-57MPI-1-10 |
| Alstom | 20X1310CRL |
| Alstom | KCC8302 |
| ABB | MCU2A02V2-4 ISCA022657R9090 |
| WOODWARD | 8440-1706 SPM-D11 |
| MOXA | EDS408A-SS-SC |