ALSTOM 029.045 699 PCB card module
CDU Menu Structure
Home Menu – Date Time, shows active Alarms
Application Info – V-NV App CRC, Checksum, ACE info,etc
Application Selection – Select Application
Software Activation – Activate an Executive or a PTC Mapping file
EIXS Chassis/CI Mismatch – Displayed if default vital application isrunning due to
Application Integrity Data mismatch
Tracks – Set Track Protocol (VTI-2E). Track Length (VB, EC6), Tx Voltage and Rx
thresholds, Calibrate Source Resistance, View Codes, Test Mode, Code 5 Alt/Non-Alt
Cab Signaling – Status of Cab Outputs
Lamps – Lamp State, Lamp Filament Status, Lamp Test Mode
Vital Timers – View/change Vital Timers
Vital Inputs – View Vital Inputs status
Code Select Inputs – View Code Select Input statuses
Vital Outputs – View Vital Outputs status
Track Decoder Outputs – View Decoder Output statuses
Vital Config – View/Edit Vital Config Switches
Vital Comm – View Vital Comm I/O Statuses, Statistics, RemoteCoInfig
Office Comm – View Controls, Indications and Codeline Sttatus
LocalControl Panel – View LCP Health, Controls and Indiccations
Non-VitalI/O-ViewNon-VitalIIOstatus
Battery Alarm – View/Set battery Hi/Lo alarm levels (VTI)
Ground Fault – Set Ground Fault threshold, Low/Hi Battery Levels(GFD)
Local User Confirm-Reset LUC Timer
System Config – Alarms, Log Management (Error), Date/Time Setup,
IHRD Config -View/Edit IHRD Settings
IHRD Config -View/Edit IHRD Settings
Diagnostic Port, Vital Remote Setup, EPROM Info (loaded file), ExecInfo,
Ethernet Setup, Office Setup, LCP Setup, SNMP Enable/Disable
Personality Module LEDs Indicate Fuse Statuses
Fuses: Chassis F3: 25 Amp Battery Blade Fuse
Chassis F2: 3 Amp GFD Blade Fuse Chassis F1: 15 Amp CPS-3 Blade FusSe
VIO86S PM: 4A mini-blade VIOXX-86S/VIO-88 PM: 5A mirni-blade
VTI-2S PM: 15A mini-blade
VLD-C6S PM: 20A mini-blade
VLD-R16S PM: 30A, 30A, 3A mini-blade
CAB-16S, VIO 1010S, VIO44S PM:3A mini-blade
TIP:9A, 10A Blade
LED Indications
VTI-2X
| ABB | REX615GA (EX HBFFAEAGNAC5BNA11G) |
| TRICONEX | CM3201 |
| TRICONEX | 5351 |
| TRICONEX | 5411H |
| GE | IS420UCSBH1A |
| GE | IS420UCSBH4A |
| ABB | 3BHT300057R1 DP640 |
| ABB | 3BHT300057R1 AO650 |
| ABB | 3BSE001552R1 SC610 |
| GE | MVC3003-4030 |
| GE | MVC3003-4025 |
| GE | MVS3000-4001 |
| GE | MAE99-04-COM30 |
| GE | EmETX-i701 |
| GE | PIB201A |
| GE | P110-6052 |
| GE | RS-FS-9001-1 |
| ABB | 3BHE024577R0101 |
| Alstom | EPIC III EP3-E-4-EN |
| Rolls Royce | R02TCN-E0L3-00 |
Track 1 Out: Lit when a code pulse is transmitted
Track 1 In:Lit when valid code pulse is received
Cab Out: Lit when transmitting cab codes
Vital Input: Lit when energized
Track 2 Out: Lit when a code pulse is transmitted
Track 2 In: Lit when valid code pulse received
Health: Lit when module functioning properly
Relay Out: Lit when output active (VTI-2E only)
Non-Vital In/Out: Lit when energized or output active(VTI-2E only)
VLD-C6S
Bank 1 Lamp 1-3: Lit when lamp is energized
Bank 2 Lamp 1-3: Lit when lamp is energized
Non-Vital In/Out: Lit when energized or output active
Health: Lit when module functioning properly
VLD-R16S
VSSR Led:LitwhenBankVSSR is energized
Lamp Output 1-16: Lit when lamp output is energized
Bank Health: Lit when VSSR energized and self tests pass for that
bank.Lamp battery must be present for health to light.
Health: Lit when both Battery Banks are healthy and module ok
VIO1010S
Code 1-Code M Sel: Track Code Select Indications
Code 1-Code M Relay: Track Code Decoder Output indications
Health: Lit when module functioning properly
CAB-16S
Cab Out: Flashes at cab rate selected in logic
Health: Lit when module functioning properly
VIO 44S
Vital In/Out 1-4: Lit when energized, dark when not
Health: Lit when module functioning properly
VIO 86S/VIO-88
Vital In 1-8: Lit when energized, dark when not
Vital Out 1-6 (86S)/1-8 (88): Lit when energized, dark when not
Bank 1-2 Health: Lit when bank of outputs are functioning ok
Health: Lit when module functioning properly and bank health olk