FOXBORO

FOXBORO FCP270P0917YZ – Foxboro Process Controller

Electrical Safety (Also see Electrical Safety Specifications Section)

ATEX flameproof; II 2 GD, EEx d IIC, Zone 1 (g) D

CSA Certifications: (h)

Division, 1 intrinsically safe, explosionproof, dust-ignitionproof

Zone certified Ex ia IIC, and energy limited Ex nA II

Division 2. Classes I, II, and III

C

CSA zone certified flameproof Ex d IIC. Also all certifications of Code C above. (g) B

FM Approvals: (h)

Division 1. intrinsically safe, explosionproof, dust-ignitionproof

Zone approved AEx ia IIC

Division 2. nonincendive, Classes I, II, and III

PHOENIX IB ST ZF 24 AI 4/SF-2750620
PHOENIX IBS 24BK-I/O-T
PHOENIX ILB BT ADIO MUX-OMNI 2884208
PHOENIX OPC5315-004-AB
PHOENIX PATG1/23 1013847
PHOENIX PLC-BSC-24DC/21
PHOENIX QUINT PS-100-240AC/24DC/10
Phoenix QUINT-DIODE/12-24DC/2×20/1×40 2320157
PHOENIX QUINT-PS-100-240AC/10
Phoenix QUINT-PS/1AC/24DC/40 2866789
PHOENIX ST-SI-UK4
PHOENIX UK3N
PHOENIX UK4-T
PHOENIX UK6N
PHOENIX UMK-SE11.25-1

FM zone approved flameproof AEx d IIC. Also all approvals of Code F above. (g) G

IECEx flameproof, Ex d IIC, Zone 1 (g) V

Optional Selections

Refer to Optional Selections below.

Mounting Bracket Set (i)

Standard Style Painted Steel Bracket with Plated Steel Bolts

Standard Style Stainless Steel Bracket with Stainless Steel Bolts

Universal Style Stainless Steel Bracket with Stainless Steel Bolts

(Not with Structure Codes LL, LM, LC, or LD)-M1-M2-M3

Blind (Solid) Cover over Standard LCD Indicator

Solid (Blind) Cover replaces Window Cover-L2

DIN 19213 Construction used with Process Connector Code 0 and 316 ss Covers with no side vents (h)

Single Ended Process Cover with M10. B7 Steel Bolting (j) (k)

Double Ended Process Cover with M10. B7 Steel Bolting; Blind Kidney Flange on Back (j) (l) (m)

Single Ended Process Cover with 7/16 in, B7 Steel Bolting; Standard Rating 25 MPa (3626 psi) (k)

Double Ended Process Cover with 7/16 in, B7 Steel Bolting; Blind Kidney Flange on Back (j) (l) (m)

Single Ended Process Cover with 7/16 in, 316 ss Bolting (j) (k)

Double Ended Process Cover with 7/16 in, 316 ss Bolting; Blind Kidney Flange on Back (j) (l) (m)

Single Ended Process Cover with 7/16 in, 17-4 ss Bolting; Standard Rating 25 MPa (3626 psi) (k)

Double Ended Process Cover with 7/16 in, 17-4 ss Bolting; Blind Kidney Flange on Back (j) (l) (m)

Single Ended Process Cover with 7/16 in, 17-4 ss Bolting; Rated 400 bar, 5800 psi, 40 MPa (k)

Not available with Span Codes A, D, or E; or Option Codes -V, -B1. -B2. -B3. or -Y-D1-D2-D3-D4-D5-D6-D7-D8-D9

Cleaning and Preparation – Not Available with Gold-Plated Sensor, Structure 2G (h)

Unit Degreased – for Silicone Filled Sensors Only

(Not for Oxygen/Chlorine/Other Fluids that may react with Silicone)

Cleaned and Prepared for Oxygen Service – for Inert Filled Sensors Only

(Not Available with Carbon Steel Covers or with Silicone Filled Sensors)

Cleaned and Prepared for Chlorine Service – for Inert Filled Sensors Only (n)

(Not Available with Carbon Steel Covers or with Silicone Filled Sensors)-X1-X2-X3

Bolting for Process Covers/Connectors – Not with DIN 19213 or Structure Codes 78 and 79 (o)

316 ss Bolts and Nuts (Pressure Derated; Not Available with -Y Option) (j)

17-4 ss Bolts and Nuts (n)

B7-M Bolts and Nuts (NACE) (j