The FBM-enabled 200 Series standard baseplate enables total system mounting capability

by providing unit increments of 2. 4. and 8 FBM positions, as well as vertical and horizontal mounting.

Features

Key features of the 200 Series Base Plate are listed below:

 for FBM-enabled baseplates:

– 2. 4. and 8 module positions combined with vertical and horizontal mounting

– Field connectable I/O termination assemblies, redundant adapters, and modules

Identifiers for each module

– DIP switches for identification of specific module backplanes

– Additional 200 series baseboards can be added without removing the

system from service (redundant bus required)

 supports FCP280/FCP270. FDC280. and FCM100Et baseboards:

– Connection for optional GPS time strobe.

All non-FDC280 module time strobe connections require a splitter/splitter.

direct connections are supported on the FDC280 baseboard.

 All baseboards are supported except the FDC280 baseboard (RH101KF):

– Connection to 2 Mbps modular fieldbus for standard fieldbus modules or 268 Kbps fieldbus for 100 series FBMs

– Splitter/terminal modules for A/B fieldbuses

– Backwards compatible with existing I/O subsystems, allowing for future expansion

No additional interface hardware required

 Primary and secondary 24 VDC power supplies and communication connections

 Dedicated keying position for individual CP-type modules (e.g. FCP280. FDC280 or FCM/FBM),

depending on the substrate type

 Passive backplane for increased system reliability.

200 Series Substrate Mounting

Most 200 series baseboards are available in three basic mounting configurations –

horizontal DIN rail mount),vertical DIN rail mount, or horizontal or vertical DIN rail mount,

but the baseboards themselves must be orientated horizontally.

Any of these mounting configurations can be used inside the cabinet,

outside the cabinet, or mounted on secure DIN rails.

The combination of a pair of modules provides redundancy at the fieldbus

module (FBM) level. In this configuration, one FBM233 is the master and the

other is the tracking module. Input points on the control station are updated

from device input points received on the network connected to the master.

Device output points (depending on the I/O driver) are written by both the

master and the trace module.

If the I/O driver detects a problem (e.g. any device loses its heartbeat), a role

switch is automatically performed, or the user can switch roles at any time via

the SMDH.

HONEYWELL 51403519-160 K4LCN-16
HONEYWELL 51403645-100 SBHM
HONEYWELL 51403776-100
HONEYWELL 51404170-175
HONEYWELL 51404203-002
HONEYWELL 51404223-001
HONEYWELL 620-0073C
HONEYWELL 82408217-001
HONEYWELL 8C-PCNT01
HONEYWELL 8C-PCNT02
HONEYWELL 8C-PCNT02 51454363-275
HONEYWELL 90088-A-9001

Leave a Reply

Your email address will not be published. Required fields are marked *