Triconex 3706A Thermocouple Analog Input
Fault and Alarm Indicators
Fault indicators identify potentially serious problems with a module. Alarm
conditions identify abnormal field conditions such as loss of power and loss of communication.
If a fault or alarm indicator is on, you should consult the appropriate section of this
chapter and take appropriate action. This action may include replacing a faulty
module or repairing a faulty circuit or device.
Identifying Fault and Alarm Conditions
You can identify alarm and fault conditions in the following ways:
• By examining the indicators on the front panel of each module and consulting this chapter.
• By using the Diagnostic Panel in the TriStation application.
For more information, see the TriStation 1131 Developer’s Guide.
EcoStruxure™ Triconex® – Tricon CX
EcoStruxure™ Triconex Safety System – superior protection for people, production and profits
We understand that you need more from your safety instrumented systems than just keeping your operations safe
you need to keep operations running continuously, avoiding any unexpected downtime or interruption that impacts profitability.
EcoStruxure Triconex – Tricon CX is the most powerful safety system from Triconex.
Leveraging the pedigree of the field-proven Tricon, Trident and Tri-GP systems,
Tricon CX is the best possible choice when safety and profitability are critical success factors.
The Tricon system is a must for clients who need to maximize the safety and
performance of their assets. If you are challenged with reducing investment and
lifecycle costs, meeting new safety standards, combating tough competitive
pressure in your markets as well as the welfare of your employees and the
environment, then the Tricon system is designed for you.
A powerful, scalable design with assurance
of continuous operation, the Tricon system complies with international safety
standards such as IEC61508 and fulfils the requirements for applications such as
Emergency Shutdown (ESD), Fire and Gas Protection (F&G), Burner Management
(BMS), High Integrity Pressure Protection (HIPPS) and Turbomachinery Control
(TMC). The redundant high availability architecture provides a flexible, robust,
reliable and powerful solution that is ideal for clients looking to achieve
environmental and safety excellence.
Overview
| GE | MVC3003-4025 |
| GE | MVS3000-4001 |
| GE | MAE99-04-COM30 |
| GE | EmETX-i701 |
| GE | PIB201A |
| GE | P110-6052 |
| GE | RS-FS-9001-1 |
| ABB | 3BHE024577R0101 |
| Alstom | EPIC III EP3-E-4-EN |
| Rolls Royce | R02TCN-E0L3-00 |
| ABB | RET615E_E HBTCBABAABCBC6BBN1XE |
| ABB | P8451 |
| ABB | P8403 |
| ABB | SPHSS13 |
| GE | DS200ADMAH1AA |
| GE | DS200SNPAH1AB |
| GE | DS3800NHVL |
| GE | DS200FCGDH1ABA |
| GE | UR-9WH |
| GE | XD1-G11 |
| WOODWARD | 8440-1935 |
Indicators are lights on the front panel of each module that identify the state of each module.
Each module includes indicators that identify the general state of the module and other indicators related to the function of the module.
The types of indicators include:
• Status indicators which identify the processing state of the module.
Each module includes a Pass, Fault, and Active indicator.
• A lock indicator which identifies whether the module is unlocked.
• Mode indicators which identify the current operating state of the controller.
(Only on MP Modules.)
• Field power and power load indicators which identify whether a power
problem has occurred. (Only on some I⁄O modules.)
• Communication indicators which identify the type of communication occurring.
(Only on MP and CM Modules.)
• Points indicators which identify whether the point is energized.
• Alarm indicators which identify alarm conditions for the controller.
(Only on MP Modules.)