Triconex

Triconex 3664 24Vdc Digital Output(Dual)

TRICONEX TRIPLE MODULAR REDUNDANCY

Tricon operation is based on the principle of safety and high plant availability, which identifies and

compensates for failed control system elements and allows on line replacement while continuing

its assigned task without interrupting the controlled process. Fault Tolerance is achieved through TMR technology.

TMR employs three isolated, parallel control systems and extensive diagnostics integrated into one

system. The Tricon system uses two-out-of-three (2oo3) voting to provide high integrity, error-free,

uninterrupted process operation with no single point of failure. Setting up applications is simplified

with the Tricon, because the TMR system operates as a single control system from the user’s point of

view. The extensive diagnostics are inherent and transparent to the programmer.

Use of the Tricon continues to expand into new industries and applications as customers require

increased system safety and/or high availability. Today, Invensys has delivered and installed Triconex

safety system solutions in over 70 countries, providing increased safety and high process uptime.

Operating principals

• Fail Safe — De-energize to trip

• Energize to trip

• Safe, available, secure

Communications

• SIL3 Peer to Peer (254 Nodes)

• OPC DA and A&E (embedded server)

• Modbus TCP/IP Master and Slave

• Modbus Serial Master and Slave

• TSAA

ABB SYN5201-2271
ABB 490176038 S200-IE8
ABB 490176049 S200-ACN
ABB 490176052 S200-OE4
BENTLY NEVADA 125808-01
ABB REM620E_1G(NBMNAAAAAABC6BBN11G)
ABB PFTL301E
ABB RDCU-12C
ABB Mr-J3-350A
HIMATRIX F35 03
HONEYWELL 05701-A-0405
ABB GJR5253100R0272 07KT98E
Honeywell 05701-A-0351
ABB 1KGT022111R42 RACK
ABB 3BSE092977R1 PP875
ABB HIEE300744R0001 UAC318AE

• Copper and Fiber Optic

• ISA Secure EDSA Level 1

Applications

• Emergency Shutdown (ESD)

• Burner Management Systems (BMS)

• Fire and Gas Systems (F&G)

• High Integrity Pressure Protection systems (HIPPS)

• Turbo Machinery Controls (TMC)

• Control of critical applications

Managing operational risks with confidence

The Tricon fail-safe and fault-tolerant controller is used extensively in high-hazard industries

where safe operations are critical and reliable operation is paramount.

In particular, the Tricon system is the only commercial off-the-shelf controller approved by

the Nuclear Regulatory Commission for Nuclear 1E applications.

Our safety and critical control solutions are supported by a dedicated team of TÜV-certified FunctionalSafety Experts and Engineers,

deplo yed globally, ensuring that expertise is always available where and when required.

A powerful, scalable design with assurance of continuous operation,

the Tricon system complies with international standards such as IEC61508 and fulfills

the requirements for applications such as Emergency Shutdown (ESD), Fire and Gas Protection (F&G),

Burner Management (BMS),High Integrity Pressure Protection (HIPPS), and Turbo Machinery Control (TMC).

The redundant high-availability architecture provides a flexible,robust, reliable,

and powerful solution that is ideal for clients looking to achieve environmental and safety excellence.

ENSURING OPERATIONAL CONTINUITY AND MANAGING OPERATIONAL RISKS

Invensys is the only automation company with the experience and

track record in safety and critical control as demonstrated by our 27

years of experience in safety systems,in excess of 8.000 installed systems,

the only approved Nuclear Regulatory Commission Commercial off-the-shelf controller

for Nuclear 1E applications,large number of TÜV certified Functional Safety Experts and Engineers,

deployed world wide, and patented Triple Modular Redundant (TMR) technology.

Leave a Reply

Your email address will not be published. Required fields are marked *