EATON XV-440-12TSB-1-10 Combination Motor Starter
F300 Megablocks are DIN-rail mounted, device couplers for Foundation™ fieldbus
or Profibus PA networks. They allow connection of field devices to the segment
trunk cable and provide short-circuit protection to the segment.
Megablocks minimize hand wiring and allow individual devices to be added to
and removed from the segment without disrupting network communication.
Megablocks are available in four, eight, and twelve port versions. Multiple
Megablocks are easily wired together to allow larger segments to be constructed.
| trionex | 9101-050F |
| GE | XAMP-1-1-2-0-0 |
| ABB | 3BHE035301R1002 UNS0121A-Z,V1 |
| ABB | SPAU140C |
| ABB | NTRL02A |
| ABB | CM30/2S0S0E0/S11 |
| MESTO | DPU-MR |
| GE | IS215AEPAH1A PART NUMBER 109W3911P001, SUBSTITUI 104W4718P001 |
| HIMA | X-AI 32 01 A |
| METSO | D201776 |
| SAMSUNG | SPAI-16 |
| ABB | 1VCF752000 |
| GE | DS200TCRAG2A |
| GE | DS200TCPDG1B |
| GE | DS200PTBAG1 |
| GE | DS200TCEAG1 |
| GE | DS200CTBAG1 |
| Metso | ITP 201 |
| Hirchmann | BRS30-16042T2T-STCZ99HHSES |
The MP-3000 Motor Protection relay includes logic to control the num
ber of starts that can occur on the motor in a given time period for cold
and hot motor conditions. Settable timers are provided to control the
time between starts and to restart a motor after a stop. Additional logic
is included for transition control of reduced-voltage starters.
2.2.1 Start Control Timers
Motors typically have limits on the number of cold starts, starts per time
period, and time between starts that are permitted without damage.
The MP-3000 incorporates these checks to prevent excessive starting
of the motor.
2.2.2 Reduced Voltage Starting
The MP-3000 provides transition and incomplete sequence detection
function for reduced voltage starting. The User can select to transi
tion based on four logical combinations of starting current and time
sequence. The incomplete sequence function can be used indepen
dently for feedback indication from the process, to trip the motor if
expected action does not occur.
2.2.3 antibackspin Timing
For certain applications, such as pumping a fluid up a pipe, the motor
may be driven backward for a period of time after it stops. The MP
3000 provides an antibackspin timer (minimum time between stop and
restart) to prevent starting the motor while it is spinning in the reverse
direction. The relay displays the timer countdown from the moment a
stop is declared by the relay.
2.2.4 Load Shedding
The MP-3000 provides a mechanical load shedding feature that can be
used to control the driven process. The load shedding function closes
a contact on an overload condition to stop addition of load until the
overload condition subsides by a set amount. Then the load shedding
contact opens and the load is restored