The Trusted CI provides the Trusted System with an intelligent Communications Interface,

acting as a relay between the Processor, other Trusted Systems, the Engineering Workstation

and third-party equipment.

Data is transferred between the TMR Processor and the Communications Interfaces using a

common interface called the Network Variable Manager. When data is read from a Trusted

System, the data is obtained from the local copy maintained on the Communications

Interface, providing a fast response.

Data writes are more complicated. If a data write simply updated the local copy and was

then relayed to the processor, the other Communications Interfaces in the system would

carry different data. This may cause problems for redundant links.

To overcome this problem, when data is written to a Communications Interface, it is first

passed to the TMR Processor and the write is acknowledged immediately by the

Communications Interface (to avoid communications delays). The processor updates its own

database and then sends the data back to all Communications Interfaces so that they all

have the same data. This can take one or two application scans. This means that subsequent

reads will receive the old data immediately after the write, until the new data has been

distributed.

All changes to CI parameters (.ini changes) loaded online do not require a power cycle, and

will take effect immediately. The Communications Interface disconnects all communications

and restarts. Communications is also restarted on an application online update and is shut

down when the application is stopped.

Application

Supported Protocols

Front Panel Serial Port

This port operates at 19200 baud on RS232. A command line diagnostic protocol is available

via this port, accessed using a TC-304-01 Maintenance Cable and a terminal program. This

protocol is not affected by the Processor Front Panel keyswitch.

Rear Serial Ports

These ports may be configured between 1200 and 115200 baud. All four ports support

RS485. port 1 supports RS232 with full handshaking and port 2 supports RS232 without

handshaking. These ports can be allocated as a Modbus Remote Terminal Unit (RTU) Slave or

Master (Modbus Master requires a T8122 or T8123 Processor Interface Adapter).

Terasaki EMW-1101A K/834/5-001B Cpu & Ram Rom Module

Modulo Cpu E Ram Rom Terasaki EMW-1101A K/834/5-001B

ABB EL3040 GAS ANALYZER PANEL

Pannello Analizzatore Di Gas ABB EL3040

ABB EL3040 GAS ANALYSIS PANEL

ABB KENT-TAYLOR ZIRCONIA ZMT OXYGEN ANALYZER PANEL ZMT/231/000000 /4112

ABB Kent-Taylor Zirconia ZMT Oxygen Analyzer Panel ZMT/231/000000/4112

Abb Kent-Taylor Zirconi Zmt Ossigeno Analizzatore Pannello Zmt / 231/000000/411 2

SCHNEIDER ELECTRIC MTZ2-40 H1 MASTERPACT CIRCUIT BREAKER 4000A 4 POLE

Interruttore Automatico Masterpact Schneider Electric MTZ2-40 H1 4000A 4 Poli

SIEMENS 6FC 3881-0KA-Z SINUMERIK 3 FA 4B

M/D TOTCO CCE-130K-E551- 01TG FORCE TRANSDUCER 4-20 mA

M/D Totco CCE-130K-E551-01TG Force Converter 4-20 Ma

M/D TOTCO CCE-130K-E551- 01TG Trasduttore Di Forza 4-20 mA

MTU ELEKTRONIK MDEC ENGINE CONTROL UNIT 5275306860

HYUNDAI UAN50C3C M1C1S168S AIR CIRCUIT BREAKER 3 POLE 5000A

Leave a Reply

Your email address will not be published. Required fields are marked *