ALSTOM MCRI01T1CD0751C Overcurrent Relay
Genisys
CodeFail – True if a valid message is not received in Link Timeout period1 or
3 consecutive invalid messages with verifiable CRC’s are received.
LinkFail – True if after activating RTS, CTS not active within 1 second.
ATCS
CodeFail – More than five XID frames being received since entering aan Asyn
Balanced Mode. 60 seconds have expired since last received frame.
LinkFail – Service signal received with Cause Field= x03.x05. x05. x009. x0B,
x0D,x13.x21. Message timeout (10s) after last retransmission of iindication
Layers
L1 – Physical – This is an internal problem in the ELX/CIO
L2 – Data Link – Problem is between ELX and radio
L3 – Network – Problem in in the radio
L4 – Transport – Problem is between the radio and the base station
L5 – Session – ELX does not implement session layer
L6 – Presentation – Problem is between the base station andoffice
L7 – Application – Problem is in ELX application software
SCS-128
LinkFail – True if a valid message is not received in Link Timeout
period orif after activating RTS, CTS not active.
UCE
| GE | PIB201A |
| GE | P110-6052 |
| GE | RS-FS-9001-1 |
| ABB | 3BHE024577R0101 |
| Alstom | EPIC III EP3-E-4-EN |
| Rolls Royce | R02TCN-E0L3-00 |
| ABB | RET615E_E HBTCBABAABCBC6BBN1XE |
| ABB | P8451 |
| ABB | P8403 |
| ABB | SPHSS13 |
| GE | DS200ADMAH1AA |
| GE | DS200SNPAH1AB |
| GE | DS3800NHVL |
| GE | DS200FCGDH1ABA |
| GE | UR-9WH |
| GE | XD1-G11 |
| WOODWARD | 8440-1935 |
| WOODWARD | TG-13 |
| KEBA | T155-WL |
Does not have LinkFail or CodeFail capability.
Chassis ID
All DIP shunt
punched out ID = 0
No DIP shunts
punched out ID = 255
Add Binary Digit Values for each shunt made (not punched out)
Binory Dielt Valum
Disclaimer: This job aid should be used for reference only and not as
a manual supplement. To fully and properly calibrate a unit, follow
FRONT-3
directions in the operations manual.
Lamp Menu
Lamp Maintenance
VID-C6S – No external resistors required to adjust lamp voltage
Manual: Set Voltage output per Bank. Set Voltage at module output, not at mp head
Automated: Set desired voltage per lamp at lamp head (ifallowed in applica
Setup cycle takes-90s.
Lamp Test Mode: Allows enabling of individual lampoutputs for maintenance,
If allowed in application logic.
VLD-R16S – Must use external resistors to adjust lamp voltage
Lamp Test Mode: Allows enabling of individual lamp outputs for maintenance
if allowed in application logic
VSSR – Status by Module and Bank
VSSR 1 and 2 can be combined to drop together or separatedepending on application
software
Lamp Statuses
Light Out – True = Light OK. False = Light Out
Lamp Driver Status
VLD-C6S – True = Steady or Flash. False = Off
VLD-R16S – True = On. False = Off, Flash or Alt Flash
Lamp Flash Status
VLD-C6S – True = Flash. False = Not Flashing
VLD-R16S – True = On. False = Off, Flash or Alt Flash
Alt Flash Status
VID-R16S (only) – True = Alt Flash. False = Steady On.off, Normhal Flash
System Configuration
Alarms – View/Erase current alarms
Log Management – View/Erase Error, Train Data (XP4) logs
Date/Time – View; Set – time zone, DST, update source
SNMP Traps – Enable/Disable and Timeout for SNMP traps
Diagnostic Port – Port communication settings and selection
Ethernet Config-Set IP,SubNet, Gateway, Trusted Source, Telnet, for
VPM-3 Ethemet ports