ALSTOM

Alstom L54E1100EC00 Communication Module

CDU Menu Structure

Home Menu – Date Time, shows active Alarms

Application Info – V-NV App CRC, Checksum, ACE info,etc

Application Selection – Select Application

Software Activation – Activate an Executive or a PTC Mapping file

EIXS Chassis/CI Mismatch – Displayed if default vital application isrunning due to

Application Integrity Data mismatch

Tracks – Set Track Protocol (VTI-2E). Track Length (VB, EC6), Tx Voltage and Rx

thresholds, Calibrate Source Resistance, View Codes, Test Mode, Code 5 Alt/Non-Alt

Cab Signaling – Status of Cab Outputs

Lamps – Lamp State, Lamp Filament Status, Lamp Test Mode

Vital Timers – View/change Vital Timers

Vital Inputs – View Vital Inputs status

Code Select Inputs – View Code Select Input statuses

Vital Outputs – View Vital Outputs status

Track Decoder Outputs – View Decoder Output statuses

Vital Config – View/Edit Vital Config Switches

Vital Comm – View Vital Comm I/O Statuses, Statistics, RemoteCoInfig

Office Comm – View Controls, Indications and Codeline Sttatus

LocalControl Panel – View LCP Health, Controls and Indiccations

Non-VitalI/O-ViewNon-VitalIIOstatus

Battery Alarm – View/Set battery Hi/Lo alarm levels (VTI)

Ground Fault – Set Ground Fault threshold, Low/Hi Battery Levels(GFD)

Local User Confirm-Reset LUC Timer

System Config – Alarms, Log Management (Error), Date/Time Setup,

IHRD Config -View/Edit IHRD Settings

IHRD Config -View/Edit IHRD Settings

Diagnostic Port, Vital Remote Setup, EPROM Info (loaded file), ExecInfo,

Ethernet Setup, Office Setup, LCP Setup, SNMP Enable/Disable

Personality Module LEDs Indicate Fuse Statuses

Fuses: Chassis F3: 25 Amp Battery Blade Fuse

Chassis F2: 3 Amp GFD Blade Fuse Chassis F1: 15 Amp CPS-3 Blade FusSe

VIO86S PM: 4A mini-blade VIOXX-86S/VIO-88 PM: 5A mirni-blade

VTI-2S PM: 15A mini-blade

VLD-C6S PM: 20A mini-blade

VLD-R16S PM: 30A, 30A, 3A mini-blade

CAB-16S, VIO 1010S, VIO44S PM:3A mini-blade

TIP:9A, 10A Blade

LED Indications

VTI-2X

Track 1 Out: Lit when a code pulse is transmitted

Track 1 In:Lit when valid code pulse is received

Cab Out: Lit when transmitting cab codes

Vital Input: Lit when energized

Track 2 Out: Lit when a code pulse is transmitted

Track 2 In: Lit when valid code pulse received

Health: Lit when module functioning properly

Relay Out: Lit when output active (VTI-2E only)

Non-Vital In/Out: Lit when energized or output active(VTI-2E only)

VLD-C6S

Bank 1 Lamp 1-3: Lit when lamp is energized

Bank 2 Lamp 1-3: Lit when lamp is energized

Non-Vital In/Out: Lit when energized or output active

Health: Lit when module functioning properly

VLD-R16S

VSSR Led:LitwhenBankVSSR is energized

Lamp Output 1-16: Lit when lamp output is energized

Bank Health: Lit when VSSR energized and self tests pass for that

bank.Lamp battery must be present for health to light.

Health: Lit when both Battery Banks are healthy and module ok

VIO1010S

Code 1-Code M Sel: Track Code Select Indications

Code 1-Code M Relay: Track Code Decoder Output indications

Health: Lit when module functioning properly

CAB-16S

Cab Out: Flashes at cab rate selected in logic

Health: Lit when module functioning properly

VIO 44S

Vital In/Out 1-4: Lit when energized, dark when not

Health: Lit when module functioning properly

VIO 86S/VIO-88

Vital In 1-8: Lit when energized, dark when not

Vital Out 1-6 (86S)/1-8 (88): Lit when energized, dark when not

Bank 1-2 Health: Lit when bank of outputs are functioning ok

Health: Lit when module functioning properly and bank health olk

Leave a Reply

Your email address will not be published. Required fields are marked *