ALSTOM

ALSTOM MT96-MPSU011 Power Module

Update Mode Button Functions

Delete PTC Files – Deletes PTC Mapping and Configuration Filesfrom CI-2

Erase CI Flash – Erases CI Flash; PTC, SNMP and any Application Filees

Format Program Files – Deletes the non-volatile file file upload area

Format Log Flash – All Log files are deleted. System, Data, Configetc…

Erase BP – Deletes all parameters from backplane. (All Setup info)

Format Site Flash* – Deletes Vital and non-vital configuration settings, SSNMP

configuration, Application and all PTC Files from the Site Flash

Erase App* – Deletes Application files from the Site Flash

Erase Configuration* – Deletes Vital and non-vital configuration seettings and

SNMP configuration from the Site Flash

Erase PTC Files* – Deletes all PTC files from Site Flash

Download Site Flash* – Downloads all the contents of the SiteFlash (Boot)

Version 5.18 or newer and Executive version 7.27 (Crossing)6.39

(Interlocking), 8.29 (Combined) or newer is required for this optionn). *Note

Available only if Site Flash is enabled. Boot Version 5.18 and Executlive

version 7.27 (Crossing), 6.39 (Interlocking),

8.29 (Combined) and newer will allow chassis backup and restore.

Ethernet Executive Upload Procedure (Recommended)

Note: It isrecommended the configuration is saved before proceeding!

Enter Update Mode as described in the Update Mode section

Select ‘Executive/Boot’ from the ‘Upload New’ drop-down, then

browse and select the Executive software file to be uploaded

If the Executive file is successfully uploaded, “File Successfully

Uploaded” will appear in the dialog box

Verify the correct build and CRC information is displayed.

To apply the Executive file, click on “Apply Executive/Boot”

When the Executive file is applied successfully, “File Applied

Successfully”, will be displayed

Activate the Executive by pressing the Activate button and following the

instructions on the Web UI. Once activated, reboot the VPM-3 by either

pressing the Reset button or cycling power on the chassis.

Ethernet Application Flash Upload Procedure

Diagnostic Telnet Connection

1. Connect to a VPM-3 with an RJ45 Cable (crossover or straight)

2. Enable the Telnet Interface through the CDU-1. CDU-2 or Web GUI

3. Using a Terminal program (Hyper Terminal, ProComm, etc) connecttothe IP

address for the VPM-3 Port connected to.

Enter username and password for the Telnet Interface.

GE IC754CGL06CTD
ABB 3BHE022287R0001
GE MCU2A02V2-4 1SCA022657R9090
Foxboro FCM10Ef P0916CP
Alstom MAE99-04
MOOG D635-706
GE IS230JPDGH1B-I
VEGA MET 602 Ex
Saab SCB5110 9240 021-203
GE IS200WROBH1A
TRICONEC 3603T
TRICON 4355X
Triconex 4000189-530
ABB PFVL142(16MM)
ABB AT868-2-1-1
ABB FVL141V-16MN

Default login: admin.

Default password: telnet

Diagnostic Serial Connection

1. Connect to CIO-1A with 9-Pin null modem cable. CIO-1AA can be addedto

any ELX unit with no other changes.

Open terminal session configured as follows

Baud*:57600

Parity: None

Data Bits: 8

Stop Bits: 1

Flow control: None

Terminal Emulation:VT100 or ANSI BBS

Data Transfer Protocol: Z Modem

*57600 is the default setting, but can be modified