ALSTOM

ALSTOM 20X4310 Data Manager

The ElectroLogIXS/EC5 consists of a chassis, motherboard, plug inmodules, a CDU (Control Display)

Unit) and Personality modules with terminal blocks for hard wiring the sysn to external relays, hazard

detectors, and signal aspects. All modules have front panel indicators thasplay module health status,

and function indicators for monitoring active I/O signals. Parameter setup and modification can be

performed via the VPM-3 Web Graphical User Interface (Web GUI) or via thhe CDU. The Web GUI is

operated by a separate computer / PDA device running an Internet Explorer (or compatible) web browser.

ElectroLogIXS Physical Description

The ElectroLogIXS may be received as a separate assembly or as partof a pre-assembled rack. It is

designed for mounting in a standard 19-inch rack, wall mounting, or innstallation on a shelf. Operating

power is supplied from a standard 12 volt battery. The battery terminals aonveniently located in the

upper right corner of the 9-Slot ElectroLogIXS chassis, and are labeled N(ative) and B (battery

positive). The battery terminals are located in the upper left section ofthe I-Slot and 4-Shot Chassis.

The ElectroLogIXS is available in 9-slot, 4-slot or 1-slot configurations, providing flexibility and

scalability depending on the application. Each configurations support the number of system modules,

but have the capability for nine (9) I/O modules (9-slot), four (4) I/O mo(4-Slot), one (1) I/O module

(1-Slot) respectively. When using a VPM-2+ processor with the ElectroLogIXS 4-slot chassis, it must be

hardware revision DAO or later.

An ElectroLogIXS system consists of a chassis assembly with plug-in modtules. The system (small) card

slots are dedicated for the Central Power Supply (CPS-2 or CPS-3), Vital Peripheral Master (VPM-2+

orVPM-3) Module, GFD-1 (Ground Fault Detector), CIO-1A (CommunicationInput/Out) Module and the

CIO-CLA Module. Two additional slots are available, and each will aecommodate a CIO-2A, CIO-2AB

CIO-MDA or CIO-PCA module. The Chassis Information Module (CI-1. CI-1. CI-2 or UCI-3) is located in the

lower right section of the 9-Slot Chassis and the upper left section of tihe I-Slot and 4-Slot Chassis.

The larger I/O module slots may have the following modules installed: VLD-C6S (Vital Lamp Driver),

VLD-R16S (Vital Lamp Driver), VLD-R8AC / VLD-R8AC12 (Vital AC Lanap Driver), VTI-2S (Vital Track

Interface), VTI-2E (Vital Track Interface), VIO-1010S (Track Code SelecInput/Track Code Decoder

Output), VIO-44S (Vital Input/Output), VIO-44R, VIO-86S/VIO12-866S\VIO24-86S|VIO50-86S|VIO-88 or

CAB-16S (Cab Enable Output). Personality modules are installed in the uppeportion of the I/O slots. The

personality module installed in a slot will depend on the I/O module innstalled in the chassis.

ElectroLogIXS Chassis

The open-frame ElectroLogIXS chassis allows easy access to all modules and plug in connections.

Mounted in the back of the chassis is a one piece backplane

that provides interconnections to all the modules of the

ElectroLogIXS system. Personality modules (Figure 1-3)

attach to the backplane and connect the modules to the field

wiring. Quick disconnect clips secure modules to the chassis

and all personality module connectors are keyed to insure that

modules are placed into the correct slot. In addition, the

personality module field wiring connectors are keyed.

I/O module slots can include: :

XTI-1S modules

VIO-44S modules

VIO-44R modules

IXC-20S modules

VTI-2S modules

VIO-1010S modules

VIO-86S modules

VIO12-86S modules

VIO24-86S modules

VIO50-86S modules

VIO-88 Modules

VLD-C6S modules

VLD-R16S modules

GE PIB201A
GE P110-6052
GE RS-FS-9001-1
ABB 3BHE024577R0101
Alstom EPIC III EP3-E-4-EN
Rolls Royce R02TCN-E0L3-00
ABB RET615E_E HBTCBABAABCBC6BBN1XE
ABB P8451
ABB P8403
ABB SPHSS13
GE DS200ADMAH1AA
GE DS200SNPAH1AB
GE DS3800NHVL
GE DS200FCGDH1ABA
GE UR-9WH
GE XD1-G11
WOODWARD 8440-1935
WOODWARD TG-13
KEBA T155-WL

Leave a Reply