FOXBORO

FOXBORO B4H254-8F8T X440G2-12T8FX-GE4

The manufacturer shall provide two-wire, 1 to 5 V dc output, absolute, gauge, or d/p Cell Transmitters (with

or without pressure seals) suitable for field mounting, that meet the following specifications:

Span Limits:

Accuracy:

LCD Indicator:

Damping:

Electronics Housing:

Modular Electronics:

RFI Protection:

Process Cover Materials:

Sensor Materials:

Process Connection:

Approvals and

Certifications:

Approximate Mass:

Model Codes:

RADISYS EPC-16
RADISYS EPC-5 W/ EXM-13
RADISYS SBC486DX66
RAMIX PMC008A 700502
RAMIX PMC237C-008EMI
RAMIX PMC661J
RAMIX PMC676TX
RAYCHEM EMDR
RELIANCE 0-51378-25
RELIANCE 0-52712 800756-21B
RELIANCE 0-54341-21
RELIANCE 0-56942-1-CA
RELIANCE 0-57100
RELIANCE 0-57170

Differential Pressure Transmitter (IDP10):

0.5 inH2O to 3000 psi, using five sensors

Bracket Mounted Absolute/Gauge Pressure Transmitters (IAP20/IGP20):

0.5 inH2O to 5000 psi, using six sensors

Direct Connected Gauge Pressure Transmitters (IGP10):

1 to 6000 psi, using four sensors

Direct Connected Absolute Pressure Transmitters (IAP10):

1 to 3000 psi, using three sensors

±0.10% of calibrated span for linear output.

Standard Liquid Crystal Display (LCD) Indicator with pushbuttons for on-board

calibration and configuration.

Settable for a range of none to 8 seconds.

Epoxy coated aluminum or 316 ss, IEC IP66 (NEMA 4X), two-compartment housing

with field wiring in one compartment and electronics in the other compartment.

Easily replaceable, modular electronics.

Maximum error shall be no more than an additional ±0.1% of calibrated span for 30

V/m field intensity between 27 and 1000 MHz.

Industry Standard 316 ss, Carbon Steel, Monel, or Nickel alloy, depending on

transmitter structure selected.

316L ss, Cobalt-Nickel-Chrome (Co-Ni-Cr), Monel, Nickel alloy, Tantalum, or 316L ss

Gold-Plated sensors, depending on transmitter structure selected.

IAP10/IGP10 Transmitters: Direct to process piping or pressure seal

with 1/2 NPT; optional Rc 1/2 or G 1/2 B external threads to process piping. Internal

1/4 NPT thread also provided as plumbing connection to the process; or prepared

for a direct connect seal, or remote capillary connected seal.

IAP20/IGP20/IDP10 Transmitters: Used with process connectors to accept

1/4 NPT, 1/2 NPT, Rc 1/4. Rc 1/2. Schedule 80 welding neck; or PVDF insert(s)

(tapped for 1/2 NPT) in process cover(s) is(are) used as process connection.

Process connection can also be prepared to accept a direct connect seal; or

prepared for a single remote capillary connected seal, or two remote capillary

connected seals. IDP10 available with traditional structure or low profile structures

(low profile structures not available with seals).

Must be suitable for Division 1 Hazardous Locations, and conform to all applicable

European Union Directives. Versions available to meet Agency flameproof and zone

requirements.

1.5 kg (3.3 lb) for Direct-connected AP and GP Transmitters

3.5 kg (7.8 lb) for Bracket Mounted AP and GP Transmitters

4.2 kg (9.2 lb) for DP Transmitters w/ Process Connectors

See inside pages for IDP10 traditional and low profile structures.

With 316 ss Housing: Add 1.1 kg (2.4 lb)

With Pressure Seals: See PSS 2A-1Z11 A

I/A Series IAP10/IGP10 Direct-connected Absolute/Gauge Pressure Transmitters;

IAP20/IGP20 Bracket Mounted Absolute/Gauge Pressure Transmitters, or IDP10 d/p

Cell Transmitters; with 1 to 5 V dc Low Power, Voltage output, with or without pressure

seals; or equivalent