Triconex 3701 0-10Vdc Analog Input
EcoStruxure™ Triconex® – Tricon CX
EcoStruxure™ Triconex Safety System – superior protection for people, production and profits
We understand that you need more from your safety instrumented systems than just keeping your operations safe
you need to keep operations running continuously, avoiding any unexpected downtime or interruption that impacts profitability.
EcoStruxure Triconex – Tricon CX is the most powerful safety system from Triconex.
Leveraging the pedigree of the field-proven Tricon, Trident and Tri-GP systems,
Tricon CX is the best possible choice when safety and profitability are critical success factors.
Applications
• Emergency Shutdown (ESD)
• Burner Management Systems (BMS)
• Fire and Gas Systems (F&G)
• High Integrity Pressure Protection systems (HIPPS)
• Turbo Machinery Controls (TMC)
• Control of critical applications
Operating principals
• Fail Safe — De-energize to trip
• Energize to trip
• Safe, available, secure
Communications
• SIL3 Peer to Peer (254 Nodes)
• OPC DA and A&E (embedded server)
• Modbus TCP/IP Master and Slave
• Modbus Serial Master and Slave
• TSAA
• Copper and Fiber Optic
• ISA Secure EDSA Level 1
KEY CAPABILITIES
| GE | DS3800NGRD1D1C |
| ABB | AO2040 |
| WOODWARD | 5463-787 |
| WOODWARD | 5501-429 |
| MOOG | D651-129B |
| ABB | HMI REF542 PLUS |
| ABB | REF615 HBFJAEAGAAC1BAA11G |
| ABB | REF615 HBFJAEAGAAC6BAA1XE |
| ABB | REM620E_F NBMNAANNABC1BNN1XF |
| ROLLS-ROYCE | H1151.0102 |
| KEBA | CU211/E |
| HONEYWELL | 50065674-702 |
| ROLLS-ROYCE | MPSF1-10.4 |
| WOODWARD | 8440-1849 |
| Uniop | eTOP307 |
| idec | FA-3S PF3S-PSA2 |
• TÜV Certified up to SIL3 applications in accordance with International standard IEC61508
• Easily integrated with all major Distributed Control Systems
• On-line module replacement ensures plant availability by hot-swapping of modules
• Works with both centralized and distributed applications
• Comprehensive family of I/O modules
• HART protocol pass through to Asset Management Systems
• Fast program cycle time for TMC applications
• Expertise available from our TÜV certified Functional Safety Experts and Engineers
• Certified for use in non-incendive applications
Tricon Key capabilities
• TÜV-certified for SIL3 applications to international standard IEC61508
• High-availability architecture for continuous operation
• Fault-tolerant architecture for continuous operation even under fault conditions
• Choice of form factors
• Online module replacement ensures continuous operation and plant availability
• Online upgrade without process interruption
• Direct Integration with Foxboro®Evo process automation system
• Easily integrated with all major distributed control systems
• ISA Secure EDSA Level 1 right out of the box
• Works in both centralized and distributed applications
• HART protocol pass through to Asset Management Systems
• Fast program cycle time from 10 mS
• 1 mS SOE Digital Input
• Choice of termination options — Direct and ETP
• Expertise available from our TÜV-certified Functional Safety Experts and Engineers
• Continually current technology
• Comprehensive family of I/O modules