Triconex

System Interface Cable Assembly 4000212-002 Triconex

Based on industry-leading Triconex™ triple modular redundant (TMR) technology,

Tricon has logged more than one billion hours with no failure on demand.

The Tricon system is certified by TÜV Rheinland for use in safety applications up

to Safety Integrity Level 3 (SIL 3).

It is also marine-certified and nuclear 1E-certified.

Features

Communications and integration

Online module replacement to ensure continuous operation and plant availability

Integration with EcoStruxure Foxboro DCS and all major distributed control systems (DCSs)

Comprehensive family of I/O modules

Up to 254 nodes of peer-to-peer communications

Achilles Level 1 cybersecurity certification

Based on industry-leading Triconex™ triple modular redundant (TMR) technology,

Tricon has logged more than one billion hours with no failure on demand.

The Tricon system is certified by TÜV Rheinland for use in safety applications up

to Safety Integrity Level 3 (SIL 3).

It is also marine-certified and nuclear 1E-certified.

Features

Communications and integration

Online module replacement to ensure continuous operation and plant availability

Integration with EcoStruxure Foxboro DCS and all major distributed control systems (DCSs)

Comprehensive family of I/O modules

Up to 254 nodes of peer-to-peer communications

Achilles Level 1 cybersecurity certification

Maintenance

Built-in diagnostics and redundancy management — transparent to user

Easy diagnostics for status and fault analysis

Online modifications and changes, online module replacement and hot spare slot

for continuous production without halting operations

Full set of software tools for every stage of the safety life cycle (TriStation™ suite)

Applications

Safety and critical control applications

– TÜV-certified for SIL 3 applications to international standard IEC61508:2010

Emergency shutdown (ESD)

Burner management system (BMS)

Turbomachinery control and protection (TMC)

– Works in both centralized plus distributed and remote I/O applications

– Suitable for use in harsh environments

The Tricon Communication Module (TCM) is compatible with Tricon v10.0 and later systems only.

Allows Tricon to communicate via Ethernet with TriStation, other Tricon or Trident controllers,

Modbus master and slave devices, and external hosts.

Each TCM contains 4 serial ports, 2 network ports, and 1 debug port (for Triconex).

Each serial port is uniquely addressed and can be configured as a Modbus master or slave.

Serial port #1 supports Modbus or Trimble GPS interface. Serial port #4 supports

Modbus or TriStation interface.

Maintenance

Built-in diagnostics and redundancy management — transparent to user

Easy diagnostics for status and fault analysis

Online modifications and changes, online module replacement and hot spare slot

for continuous production without halting operations

Full set of software tools for every stage of the safety life cycle (TriStation™ suite)

Applications

Safety and critical control applications

– TÜV-certified for SIL 3 applications to international standard IEC61508:2010

Emergency shutdown (ESD)

Burner management system (BMS)

Turbomachinery control and protection (TMC)

– Works in both centralized plus distributed and remote I/O applications

– Suitable for use in harsh environments

The Tricon Communication Module (TCM) is compatible with Tricon v10.0 and later systems only.

Allows Tricon to communicate via Ethernet with TriStation, other Tricon or Trident controllers,

Modbus master and slave devices, and external hosts.

Each TCM contains 4 serial ports, 2 network ports, and 1 debug port (for Triconex).

Each serial port is uniquely addressed and can be configured as a Modbus master or slave.

Serial port #1 supports Modbus or Trimble GPS interface. Serial port #4 supports

Modbus or TriStation interface.

Leave a Reply

Your email address will not be published. Required fields are marked *