EATON SDN90186 MOTOR CONTROL CENTER
The HCU16 HART units connect to 16 general purpose field instruments
while maintaining channel to channel isolation. Resistor conditioning
options are compatible with all types of I/O cards. It allows pass-through
connections for transmitter power supply, input signal and common.
The HCU16AO unit includes HART filters for use with I/O cards that are
incompatible with HART communication signals.
Customised backplanes and connection units are available to provide
direct connection from DCS I/O cables, replacing the standard termination
boards.
Solution-oriented and multifunctional
The devices‘ application oriented functions reduce the number of slice
cards required. This means, for instance, that digital outputs can be powered
and fused in groups, as well as switched off centrally. In addition, digital inputs
can perform additional counter functions, while analog modules include
additional functions such as a reference voltage, temperature measuring,
cold-junction compensation, etc.
| GE | IS230JPDGH1B-I |
| VEGA | MET 602 Ex |
| Saab | SCB5110 9240 021-203 |
| GE | IS200WROBH1A |
| TRICONEC | 3603T |
| TRICON | 4355X |
| Triconex | 4000189-530 |
| ABB | PFVL142(16MM) |
| ABB | AT868-2-1-1 |
| ABB | FVL141V-16MN |
| Meggitt | IOC-CARD FOR MPC4 200-560-0001HH |
| GE | DS200TCDAH1B |
| GE | DS200TCPSG1A |
| Yokogawa | S2CP471-01 S2CP471-01 |
| Prosoft | MVI56-PDPS |
| GE | DS200TCDAH1B |
| Uniop | ETOP515U3P1 |
| GE | 350-L-P5-G5H-E-E-C-P |
| GE | IS420UCSBH3A |
The MTL4851 and MTL4852 HART connection system provides a simple
interface between smart devices in the field, control systems and HART
instrument management software run on a pc.
The system is based on 16-channel modularity to provide a compact,
easily configurable and expandable system. Using a standard RS485 serial
link up to 7936 HART devices can be connected on a single network.
For the optimum solution, choose from a range of general purpose
and IS termination boards. For maximum flexibility the HMM64 HART
backplane locates an MTL4851 master communications module and
up to three MTL4852 secondary interface modules, with each module
connecting to 16 field devices. General purpose HART connection units
and IS backplanes are available fitted with an cable interface connection
to the HMM64. This system can be extended with further HMS64 HART
backplanes linked to the master, each carrying up to four MTL4852
secondary interface modules.
With the XN300. you can rest assured knowing that you will find the ideal
configuration for the exact system solution you want.
The various modules are functionally designed for practical applications, minimizing
the amount of devices needed. This not only goes easy on your wallet, but also reduces
the amount of space required Convenient and easy to wire A plug-in connection system
makes it possible to quickly connect and replace modules,which in turn makes it much
easier to commission and service machines. Each module can accommodate up to 20
channels, which are distributed among five plug connectors as required for the application
at hand.