Eaton

EATON CORPORATION JDB2225 CIRCUIT BREAKER

Configure through a Telnet Connection

To configure the card parameters through a Telnet connection:

1. Run your Telnet utility to connect to the card. The card’s default IP

address is 192.168.7.18.

2. Open the connection. A login prompt displays.

3. Enter your username and password. The menu of the ConnectUPS

device displays. The default username and password is admin.

4. Configure the card parameters as described in “Configuration Menu

Settings” on page 39.

Install Shutdown Software

Refer to the Quick Start Instructions to install the NetWatch shutdown

software. For other software, such as LanSafe® Power Management

Software or PowerVision Software, refer to those user guides for

installation and configuration instructions.

You can manage the UPS from a Web browser or from an SNMP

network management system.

UPS Management from a Web Browser

When using a Web browser to access the ConnectUPS Web/SNMP

Card, the majority of UPS-related information is available by selecting

any of the following menu options:

Summary

UPS History

Configuration

Control

Registered Clients

Language

Help

Siemens 6ES7326-2BF10-0AB0
Siemens 6ES7331-7TF01-0AB0
Siemens 6ES7331-7TB00-0AB0-
Siemens 6GK1503-3CC00
ABB 70EA04b – E HESG492059
GE IS230JPDGH1B
GE DS3800HPRB1D1C
GE DS200DCFBG1ALC
UniOP eTOP40B-0050
ABB PM866AK02 3BSE081637R1
SARTORIUS MDB-8E
ROLLS-ROYCE SLIO 02
Bently Nevada 3500/22M-01-01-01
Alstom UT150-2
EMERSON PR6423 009-041+CON 041/913-030
Honeywell HCIX15-TE-FA-NC
KEBA D3-DU 360/A-2100-20
SARTORIUS MDB-8E

Each menu and submenu selection has online help available

The FP-4000 takes full advantage of its microprocessor technology,

providing the user new freedoms and a wealth of data-gathering

features. The relay performs self-checking of all major hardware and

firmware protection elements to ensure their operation in the event of

a system or component electrical failure or fault. Protection functions

are well suited for main and distribution feeder circuit applications.

Programmable logic control functions make the FP-4000 relay ideally

suited for main-tie-main and main 1/main 2 transfer schemes.

The zone interlocking feature can be utilized for bus protection instead

of an expensive and complicated bus differential (87B) scheme.

The FP-4000 works directly with the Cutler-Hammer Digitrip 3000

and Digitrip MV relays. New breaker failure logic provides faster

remote backup clearing times for stuck breaker operation.

The FP-4000 provides trip and close circuit monitoring and alarming

features. It continually monitors the complete trip and close circuits

for continuity and readiness to trip. Open and close pushbuttons are

conveniently located on the front of the relay for local breaker operation.

Loss-of-vacuum monitoring is activated when the breaker is open.

Residual current is monitored and alarmed if detected.

Eaton operates an independent development center, the ‘Cybersecurity

Center of Excellence’ (CCoE), specifically designed to combat the threats

posed by cyber attacks. All Eaton products are regularly qualified for

secure operation.

Leave a Reply

Your email address will not be published. Required fields are marked *