ICS Triplex

ICS TRIPLEX T8300 | Trusted TMR Expansion Chassis

The Trusted® TMR 24 Vdc Digital Input module interfaces to 40 field input

devices. Fault tolerance is achieved through a Triple Modular Redundant

(TMR) architecture within the module for each of the 40 input channels.

Each field input is triplicated and the input voltage is measured using a

sigma-delta input circuit. The resulting field voltage measurement is

compared to user configurable threshold voltages to determine the reported

field input state. When a line-monitoring device is installed at the field switch,

the module can detect open and short circuit field cables. Line monitoring

functions are independently configured for each input channel.

The triplicated voltage measurement, coupled with onboard diagnostic testing,

provides comprehensive fault detection and tolerance.

The module provides onboard Sequence of Events (SOE) reporting with a

resolution of 1 ms. A change of state triggers an SOE entry. States are

determined by voltage thresholds that can be configured on a per channel

basis.

ABB PSM02
ABB PSM03
ABB TRM01
ABB BIO01
ABB PIO01
GE IS420ESWBH3A TE1W031
ABB RED670 1MRK004810-KG
GE DS3800HMHA
Eaton MTL F809F-Plus
ULSTEIN PIB1039A
TRICONEX 3723X
TRICONEX 3506X
TRICONEX 3626X
ABB 1SDA104922R1
ABB PSE105-600-70
TRICONEX 3506X
ALSTOM Micom C264
HIMA H4116 992411602
ABB REF615C_E IED

Data is transferred between the TMR Processor and the Communications Interfaces using a

common interface called the Network Variable Manager. When data is read from a Trusted

System, the data is obtained from the local copy maintained on the Communications

Interface, providing a fast response.

Data writes are more complicated. If a data write simply updated the local copy and was

then relayed to the processor, the other Communications Interfaces in the system would

carry different data. This may cause problems for redundant links.

To overcome this problem, when data is written to a Communications Interface, it is first

passed to the TMR Processor and the write is acknowledged immediately by the

Communications Interface (to avoid communications delays). The processor updates its own

database and then sends the data back to all Communications Interfaces so that they all

have the same data. This can take one or two application scans. This means that subsequent

reads will receive the old data immediately after the write, until the new data has been

distributed.

All changes to CI parameters (.ini changes) loaded online do not require a power cycle, and

will take effect immediately. The Communications Interface disconnects all communications

and restarts. Communications is also restarted on an application online update and is shut

down when the application is stopped.

The Trusted® Processor is the main processing component in a Trusted System. It is a powerful,

user-configurable module providing overall system control and monitoring facilities and processes

input and output data received from a variety of analogue and digital Input / Output (I/O) modules

across a Trusted TMR Inter-Module Communications Bus.

The range of applications for the Trusted TMR Processor vary in integrity level and include fire and

gas control, emergency shutdown, monitoring and control, and turbine control.