Modules in the I/O Manager

If you want to use ibaBM-ENetIP with ibaPDA, you have to configure the device in the

ibaPDA I/O Manager. Use the step-by-step procedure described in chapter 9.1.

In the following paragraphs, we describe the available modules.

“ibaBM-ENetIP“ device module

The module “ibaBM-ENetIP” contains of 4 different tabs. The “General” and “Diagnos

tics” tabs are always visible. The “Analog” and the “Digital” tab contain dynamic online

views of the analog and digital signals acquired by the device. This is why these two tabs

are only visible after modules of „EtherNet/IP sniffer“ type have been added and the

configuration has been transferred to the device.

Locked

A module can be locked in order to prevent accidental or unauthorized changes in the

module settings.

❑ Enabled

Disabled modules are excluded from signal acquisition.

❑ Name

Enter here the name for the module as clear text.

❑ Timebase

Timebase for the data acquisition which is used for this device in ms. Cycles of down to

1 ms are possible (depending on the number of the signals).

❑ Use name as prefix

The module name is placed in front of the signal name as prefix.

Connection

❑ IP address

IP address of the device (via FO); cannot be changed.

❑ Auto enable/disable

If the value is TRUE, the data acquisition is started even though the device is miss-ing.

The missing device is temporarily disabled in the configuration. During the measurement

process, ibaPDA tries to re-establish the connection to the missing device. If this is suc

cessful, the measurement is restarted automatically including the device that has been

missing. If the value is FALSE, the measurement will not be started, in case ibaPDA

cannot establish a connection to the device.

9.2.1.2 “Analog“ tab

If analog signals have been configured in the modules „EtherNet/IP sniffer“ and the con

figuration has been transferred to ibaBM-ENetIP, you will see here an overview of all

acquired analog signals with an online overview of the currently acquired values.

“Digital“ tab

If digital signals have been configured in the modules „Device slot“ and the configuration

has been transferred to ibaBM-ENetIP, you will see here an overview of all acquired

digital signals with an online overview of the currently acquired values.

IPFAN12 Fan Unit   230 Vac
2RCA025059A0901 Control of AC and DC   power circuits
2711-K6C16 PanelView Standard Operator   Terminals
51304754-176 MC-PAIH03 High Level Analog   Input Processor-16 Inputs
02000-A-1645 Series 2000 Calibration Flow   Housing Assembly
FC-SSWM01 SC SWITCH MODULE   PROGRAM/FORCE/RESET
FC-TSPKUNI-1624 Safe Functional Test   Adapter (FTA)
FC-GMLA16 16-Channel Digital Input FTA   Dual Channel CC
FC-TPSU-2430 Safety Manager System Module
FC-SAO-0220M HONEYWELL Safe Digital   Output FTA
FC-TSDO-0824C HONEYWELL Safe Digital   Output FTA
560PSU02 R0001 1KGT011900R0001   Communication unit ABB
SPCJ4D34-DASPAJ 140 C Overcurrent and   earth-fault relay
REF615 HCFKAEADABC2BAA11E聽 Feeder   Protection and Control
8220-DI-IS8-channel Intrinsically Safe   RTD input
REM615C_E Motor Protection and Control
8215-DO-IS 8-channel Intrinsically Safe   RTD input
8205-TI-IS 8-channel Intrinsically Safe   RTD input
S71202-NANANA servo driver KOLLMORGEN
FX-USI-0002 Safety Manager System Module
833-004563-007 Radio-frequency matcher   Suitable
853-028873-510 Radio-frequency matcher   Suitable
810-028296-173 Radio-frequency matcher   Suitable
810-800256-207 Radio-frequency matcher   Suitable
839-195167-001 Radio-frequency matcher   Suitable
772-032738-005 SMC regulator

Leave a Reply

Your email address will not be published. Required fields are marked *