YOKOGAWA

YOKOGAWA YNT511D ER Bus Terminator

The Yokogawa YNT511D is a specialized Bus Terminator module designed for use with the ER Bus (Extended Remote I/O Bus) in the CENTUM VP and CENTUM CS 3000 Distributed Control Systems.

It is a critical passive component used to maintain signal integrity across long-distance communication lines.

1. Introduction

The YNT511D is a terminator for the ER Bus, which connects a Field Control Unit (FCU) to remote I/O nodes.

In any high-speed communication system using coaxial or serial lines, signal reflections can occur at the end of the cable, leading to data corruption and communication errors.

The YNT511D is installed at the end-of-line position to absorb these signals, ensuring clear and stable communication between the EB401 (Master) and EB501 (Slave) modules.

2. Technical Parameter Table

Feature Specification
Model Code YNT511D
Component Type ER Bus Terminator (for Duplexed/Redundant configurations)
Impedance 75 $\Omega$ (Matched to YCB141 Coaxial Cable)
Connector Type BNC
Bus Compatibility ER Bus (IEEE802.3 10BASE-2 compatible)
Configuration Dual-termination (Supports redundant A/B lines)
Mounting Direct connection to BNC “T” connector or Bus Adapter
Operating Temp -20°C to +70°C

3. Related Models

The YNT511D is part of the physical layer of the ER Bus network. Related components include:

EB401: ER Bus Interface Master Module (FCS side).

EB501: ER Bus Interface Slave Module (Remote Node side).

YCB141: 75 $\Omega$ Coaxial Cable used for the ER Bus backbone.

YNT511S: The “S” version, typically used for Single (non-redundant) bus configurations.

YCB147 / YCB149: Bus Adapter Units used for branching or grounding the coaxial segment.

YNT511D

YNT511D

4. Product Advantages and Features

Signal Integrity: Effectively eliminates electrical “noise” and signal reflections, which is vital for maintaining the 10 Mbps data rate over long distances.

Redundancy Ready: The “D” in YNT511D signifies its design for Duplex (redundant) systems, providing termination for both the primary and backup communication lines.

Reliability: As a passive component with no electronic logic, it has an extremely long service life and is highly resistant to environmental stressors.

Easy Installation: Uses standard BNC connectors for quick “twist-and-lock” attachment to the end of a bus segment.

arcom SHIM-8CE
AREVA MVAJ27T1FB0784D
AREVA MVAJ21T1GB0771B
AREVA MVAJ23T1GB0774B
ASCO H117AL112F1
ASEM HT2150/S0
ASM 4552200
ASML MC1AB37   4022.437.1856
ASML DPEM-440A   4022.455.16371
ASML 4022.471.7412  6001-0303-5701
ASTEC AM80A-150L-065F33
ASYST SB-700

5. Application Cases

Remote I/O Extension: Used in any plant where I/O racks are located in a different building or area than the main controller, requiring an ER Bus link.

Offshore Platforms: Ensuring stable data transmission between different decks of a platform where electromagnetic interference (EMI) from large motors is common.

System Maintenance: Often replaced during “Communication Error” troubleshooting to rule out faulty termination as a cause of network instability.

6. Other Models in the Same Series

YNT511S: For single-bus architectures.

YNT522D: A terminator variant for different bus types or older legacy Yokogawa networks.

AIP121: While a coupler, it often works in tandem with YNT series terminators to manage segment transitions.