YOKOGAWA

YOKOGAWA EB501 ER bus interface slave module

The Yokogawa EB501 is a critical ER Bus Interface Slave Module used within the CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS).

It functions as the communication bridge for Remote I/O (ER Bus) nodes, allowing field control units to manage I/O modules over long distances.

1. Introduction

The EB501 is installed in an ER Bus Node Unit (such as the ANR10). Its primary role is to facilitate communication between the Field Control Unit (FCU) and the Remote I/O modules.

It converts the signals from the ER Bus (which typically uses coaxial cabling) into data that the local I/O modules can process.

This allows for a decentralized control architecture where I/O racks can be placed closer to the actual field instruments, reducing wiring costs.

2. Technical Parameter Table

EB501

Feature Specification
Model Code EB501
Module Type ER Bus Interface Slave Module
Communication Speed 10 Mbps
Physical Interface IEEE802.3 10BASE-2 (1 Port)
Connector Type BNC
Max. Distance 185 m (using YCB141 coaxial cable)
Current Consumption 0.7 A (at 5V DC)
Operating Temp -20°C to +70°C (requires 10 min warm-up below 0°C)
Redundancy Supported (Dual-redundant configuration available)
Weight Approx. 0.3 kg

3. Related Models

The EB501 works as part of a master-slave pair. Related components include:

EB401: The ER Bus Interface Master Module, installed in the Field Control Unit (FCU) side.

ANR10: The ER Bus Node Unit (the rack/nest where the EB501 is housed).

YCB141 / YCB311: Specialized coaxial cables used to connect the EB401 to the EB501.

YCB147 / YCB149: Bus adapter units used for cable transitions or grounding.

4. Product Advantages and Features

Extended Range: Allows I/O nodes to be located up to 185 meters away from the controller, which can be further extended using repeaters.

Environmental Robustness: Features an optional G3 Corrosive Gas Resistance coating and a wide temperature range, making it suitable for harsh industrial environments.

High Reliability: Supports dual-redundant configurations. If one EB501 module or cable fails, the system automatically switches to the standby unit without process interruption.

Easy Diagnostics: Equipped with status LEDs on the front panel to indicate communication health and hardware status.

ALSTOM PIB310 3BHB0190
ALSTOM PIB1201A   3BEC0067
ALSTOM 43297029
ALSTOM MAVS01L1AB0751D
ALSTOM MCGG62N1CB0753F
ALSTOM MFAC14K1AA0001A
ALSTOM MVAW11B1AB9007A
ALSTOM MAVS01L1AB0501D
ALSTOM MVAJ27L1FB0784D
ALSTOM MVTU11K1CD0751G
ALSTOM MVAW11B1AB0513A

5. Application Cases

Large Refineries: Used when I/O points are distributed across multiple remote “satellite” instrument houses far from the central control room.

Water Treatment Plants: Managing pumping stations located in different parts of a large facility using a single central DCS.

Retrofitting Legacy Systems: Often used when migrating from older Yokogawa XL or CENTUM V systems to CENTUM VP, as it supports similar remote wiring topologies.

6. Other Models in the Same Series

EB501-10: Basic type for standard temperature and non-explosion-proof areas.

EB501-50: Enhanced type, often including ISA G3 conformal coating for protection against corrosive atmospheres.

EB501-13: A specific variant typically utilized in newer CENTUM VP R5/R6 configurations.

EB501

Leave a Reply

Your email address will not be published. Required fields are marked *