Woodward

Woodward IKD-OUT-16 16 DO Expansion Card 8440-2306

Woodward IKD-OUT-16 16 DO Expansion Card  8440-2306

IKD-IN-16 Unique Features

16 configurable digital inputs

plug-n-play connection with Wood

ward power management controls

easy integration with PLC

compact remote I/O with IKD-OUT-16

Shorter lead time

Digital Input Expansion Module

The IKD-IN-16 is a smart solution to increase number of digital inputs to Woodward power man

agement controllers or apply it as a remote input module in your PLC based control system. It is

possible to connect one or more IKD-IN-16 modules (see table Related Products below).

The IKD-IN-16 input status are transferred over the CAN bus to a higher-level controller. Configura

tion of each input such as name, alarm class, NO/NC configuration, and time delay is performed in

the main controller. The name and class are displayed on the connected genset controller’s dis

play. It requires no configuration tool as few parameters such as module address and CAN baud

rate can be setup by onboard DIP switches.

16 configurable discrete inputs

CAN bus communication to the higher-level controller

The control unit evaluates the status of these discrete inputs and depending on the configura

tion of the control unit takes an appropriate action

The IKD-IN-16 can be used with other manufacturer’s controllers/PLCs. Consult product man

ual 37953 for information regarding the CAN bus data telegram

DIP switches to configure device module number and CAN baud rate.

Power, CAN, and DI status LEDs

Power supply ………………………………………………….12/24 VDC (9 to 35 VDC)

Intrinsic consumption ………………………………………………………..  max. 2 W

Reverse voltage protection ………………………………………………………..  Yes

Ambient temperature (operation) ……………….. -25 to 70 °C / -13 to 158 °F

Ambient temperature (storage) …………………. -30 to 80 °C / -22 to 176 °F

Ambient humidity…………………………………………….. 93%, non-condensing

Discrete inputs …………………………………………………………….. non-isolated

Input range …………………………………………………… 12/24 VDC (0 to 60 VDC)

Common terminal ………………………………. connected to battery minus (B-)

CAN Interface ………………………………………………………………………… isolated

Insulation voltage (continuous) ………………………………………………. 2500 VDC

Version ……………………………………………………………………………….. CAN bus

Internal line termination …………………………………………… yes (terminals 5.6)

Housing DIN-rail mounting ……………………………………………. Plastic housing

Dimensions  WxHxD …………………………….. 107.6 × 89.7 × 60.7 mm

Connection …………………………………………….. screw-plug-terminals 2.5 mm²

Protection system ………………………………………………………………………. IP20

Weight …………………………………………………………………………..approx. 250 g

Disturbance test (CE) ………… tested according to applicable IEC standards

Listings  ………………………………………………………… CE, UKCA, UL(Pending)

Supported power management controls

Max. # of IKD-IN-16

easYgen-3000XT (GC-3400XTP1)   2 (1)

easYgen-3400/3500P1 and -3100/3200P2   2

easYgen-3400/3500P2 and -3100/3200P1   1

easYgen-2000   1

easYgen-1500/1700/1800   1

easYgen-800   1

DTSC-200 and -200A   1

Digital input expansion module IKD-OUT-16 (Product spec #37954): P/N 8440-2305

Digital I/O expansion module IKD 1 (Product spec #37171): P/N: 8440-2116

The digital inputs are read by the IKD-IN-16 and

transferred via the CAN bus to the control unit (incl.

alarm class). Each alarm input may have a delay as

well as the control logic (NO/NC) configured individ

ually during set up. The status of the alarm input is

monitored in the control device and will show the

alarm text in its display. The alarm class assigned in

the control device evaluates the alarm input and re

acts accordingly. If a discrete input on the IKD-IN

16 is enabled, the control device displays a text

message, and the control functions of the alarm

class are executed (refer to according manual of the

supported control devices).