Emerson

EMERSON PR6426010-110+C0N021916-240 32mm Eddy Current Sensor

32mm Eddy Current Sensor

Non-contact sensor designed for critical turbo machinery applications such as

steam, gas and hydro turbines, compressors, pumps and fans to measure radial

and axial shaft displacement: position, eccentricity and motion

Dynamic Performance

Sensitivity

Air Gap (Center)

Long Term Drift

Range

Target

Static

Target/Surface Material

Maximum Surface Speed

Shaft Diameter

Environmental

2 V/mm (50.8 mV/mil) ≤ ±1.5% max

Approx. 5.5 mm (0.22”) Nominal

< 0.3%

±4.0 mm (0.157”)

Ferromagnetic Steel

(42 Cr Mo 4 Standard)

2.500 m/s (98.425 ips)

≥200 mm (7.87”)

Operating Temperature Range

Temperature Excursions <4 Hours

Maximum Cable Temperature

Temperature Error (at +23 to 100°C)

Pressure Resistance To Sensor Head

Shock and Vibration

Physical

Material

Weight (Sensor & 1M Cable, no Armor)-35 to 175°C (-31 to 347°F)

200°C (392°F)

200°C (392°F)-0.3%/100°K Zero Point

<0.15%/10°K Sensitivity

6.500 hpa (94 psi)

5g (49.05 m/s2) @ 60Hz @ 25°C (77°F)

Linear Measuring Range

Initial gap-2.0-4.0-6.0-8.0-10.0-12.0-14.0-16.0-18.0-20.0-4.0-3.2-2.4-1.6

1.5 2.3 3.1 3

,9-0.8

0.0 0.8 1.6 2

4.7 5.5 6.3 7

,4

,1

7.9 8.7 9.5

3.2 4.0 Amplitude

[mm]

Uout

[V]

34 mm

8 mm

Mode -2… -18V

Mode -4… -20V

80 mm DIAMETER CLEAR

OF FERROUS MATERIAL

32 mm

80 mm

40 mm

40 mm

Sleeve – Stainless Steel, Cable – PTFE

~800 grams (28.22 oz)

Compliance and Certifications

CE 2014/30/EU (EN 61326-1)

2014/34/EU

2011/65/EU

ATEX EN 60079-0

EN 60079-11

IEC-Ex IEC 60079-0

IEC 60079-11

IEC 60079-26

CSA CAN/CSA-C22.2 NO. 0-M91

CAN/CSA-C22.2 NO. 157-92

CAN/CSA-C22.2 NO. 213-M1987

CAN/CSA-E60079-15-02 (R2006)

CAN/CSA-C22.2 NO. 25-1966

CAN/CSA-C22.2 NO. 61010-1-04

ANSI/UL Standard 913-2004

ANSI/UL Standard 1604-1995

UL 60079-15 2002

UL 61010-1

Hazardous Area Approvals

Intrinsic Safety (iA)

ATEX / IEC-Ex Area classification depends on converter,

see converter documentation for details,

sensor temperature classification:

T6: Ta ≤ 84°C

T4: Ta ≤ 114°C

T3: Ta ≤ 160°C

CSA Area classification depends on converter,

see converter documentation for details,

sensor temperature classification:

T6: Ta ≤ 64°C

T4: Ta ≤ 114°C

T3: Ta ≤ 160°C

Non-sparking (nA)

CSA Area classification depends on converter,

see converter documentation for details,

sensor temperature classification:

T6: Ta ≤ 64°C

T4: Ta ≤ 114°C

T3: Ta ≤ 160°C

Leave a Reply